Assessing the energy use and IAQ of various HVAC systems during the early design stage

The early design stage of a building is decisive for describing the concept of the HVAC system. Designers and practitioners can adjust and optimize the design during this stage as it provides them with enough resilience to adapt new changes. In practice, a well-defined optimization process is essentially required in order to achieve the project’s goals within a reasonable time span. These goals vary from one project to another, and sometimes they require a comprehensive study to identify the factual and stochastic parameters and their impact on the design.

The assessment of surface condensation risk in dwellings. The influence of climate in Spain

Surface condensation risk is a fact that has to be dealt with when buildings are airtight. Airtight buildings with lower ventilation rates are the result of applying energy saving policies and criteria. Surface condensation risk depends greatly on the ventilation rates, as well as on another factors such as generation of water vapour, climate, envelope components and U value, etc.

Evaluation of Low-Cost IAQ Monitors

    

Economics of indoor air quality (IAQ)

    

An update on the French indoor air quality observatory recent results: focus on ventilation and perspectives

The French indoor air quality observatory (OQAI) was set up by the French authorities in 2001 with the objective to collect data on indoor pollutants in various indoor environments to be used for public policies. Funded exclusively by public funding, the OQAI is coordinated by the scientific and technical center for building (CSTB) and involved an extensive network of partners across France in charge of the field campaigns and the laboratory analyses. To date, nationwide surveys were carried out in dwellings (2003-2005), schools (2013-2017), and office buildings (2013-2017).

Occupancy controlled ventilation in refurbished office building, combining presence and CO2 detection

From September 2015 to March 2016, UTC engaged in a major refurbishment of its Design and Research Center located in Culoz (France).

The new air tightness class in ductwork - Aeroseal technology to seal leakages in new/retrofit ductwork and duct components - the foundation for highest energy efficiency in ventilation systems

Aeroseal technology utilizes air laden with fine aerosol particles (2-20 μm) to pressurize a duct system, resulting in deposition of those particles at the leaks within that duct system. By reducing leakages of duct systems by 90% in average Aeroseal sealing technology allows reducing leakages to a standard better as air tightness class D or ATC 1 for a complete system. Aeroseal technology can be applied in new constructions as well as in existing systems to improve energy efficiency, cleanliness of ventilation systems, IAQ and comfort.

Pages