The effectiveness of mechanical exhaust ventilation in dwellings

Ventilation systems play an important role in providing a good indoor air quality in dwellings. Mechanical exhaust ventilation systems implement natural vents to supply outdoor air to the dwelling. Natural driving forces, i.e. wind and thermal draught, influence the flow rates through these supply vents. Therefore, the flow rates depend on the weather conditions and vary in time. This study considers the influence of the wind and thermal draught on the operation of a mechanical exhaust ventilation system in a reference dwelling.

Demand controlled ventilation in school and office buildings: lessons learnt from case studies

Demand controlled ventilation (DCV) refers to a ventilation system with air flow rates that are controlled based on a measurement of an indoor air quality (IAQ) and/or thermal comfort parameter. DCV operates at reduced air flow rates during a large amount of the operation time. Due to this decrease, less energy is needed for fan operation and heating/cooling the supply air. However, uncertainty still exists about the IAQ performance and ventilation efficiency in the room, especially at lower air flow rates.

VIP 36: Metrics of Health Risks from Indoor Air

In a recent review of 31 green building certification schemes used around the world, IAQ was found to contribute to only 7.5% of the final score on average. As policy makers strive to reduce the energy demands of buildings by sealing or reducing outdoor air ventilation rates, an unintended consequence could be the reduction in the quality of indoor air with corresponding negative health effects at a population scale. This article summarizes the discussions of an Air Infiltration and Ventilation Centre workshop on IAQ metrics held in March 2017.

IAQ assessment in high performing buildings

            

Development of a Seasonal Smart Ventilation Controller to Reduce Indoor Humidity in Hot-Humid Climate Homes

Controlling indoor humidity is important in homes, because high indoor humidity is associated with occupant health and building durability issues. Ventilation is often used to avoid peaks of moisture in homes, such as in kitchens and bathrooms. However, in hot-humid climates, outdoor air can have higher humidity than indoors, and continuous whole house ventilation can lead to increases in indoor humidity levels.

Energy saving as a consequence of the proposed change in Spanish regulations relating to indoor air quality

Recently research at the Eduardo Torroja Institute for construction sciences proposes a new wording for the IAQ regulations for dwellings included in the Spanish Building Code.
The main goal of the earlier research was to adapt required ventilation rates to real needs to achieve a reduction of ventilation rates and energy demand with no negative impact on indoor air quality.

Energy and IAQ friendly variable ventilation rates, according with the proposed indoor air quality regulations included in the Spanish building code.

The Spanish Building Code (BC) regulates indoor air quality (IAQ) requirements in dwellings by establishing threshold continuous flow rates according to the occupancy, use of the rooms and their usable area. The implementation of this threshold flow allow adequate IAQ.
A revised IAQ requirement have been proposed. These new requirement quantifies the IAQ as a function of CO2 concentration which means an non continuous flow rates ventilation systems will be able to be used.

How the filtration of the incoming air decreases the particle concentration within a school equipped with a balanced ventilation system

To study the impact of the filtration efficiency level on the particle concentration in a rural school equipped with a balanced ventilation system with heat recovery, measurements of indoor and outdoor particle concentrations have been carried out by using three different efficiency filters. The tested filters are respectively classed G4, F7 and F9 according to NF EN 779 (2012).