Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

The research question of this report is “Is it possible to save energy by lowering the bedroom temperatures in winter”. In this paper first the literature on optimum sleeping temperatures is investigated.
Regina Bokel, Jiahui Cai, Priyadarshini Nanda, Tessa Rouwenhorst, EU
In a recently built zero-carbon neighborhood, demand controlled exhaust ventilation systems (DCMEV) and mechanical ventilation systems with heat recovery (MVHR) are compared under operational conditions, with focus on the energy performance of bot
Ella Derycke, Wolf Bracke, Jelle Laverge, Arnold Janssens, EU
The air tightness of eight apartment buildings containing six to eleven units each on three or four floors has been tested with and without guard-zone pressure, i.e. with and without consideration of internal leakages.
Angela Rohr, Andreas Kaschuba-Holtgrave, Stefanie Rolfsmeier, Oliver Solcher, EU
The Proceedings of the 39th AIVC Conference "Smart Ventilation for Buildings", held in Antibes Juan-Les-Pins, France, on 18-19 September 2018.
AIVC, EU
Mechanical ventilation is vital in modern homes to insure adequate indoor air quality.
Danny Parker, Eric Martin, Karen Fenaughty, Delia D’Agostino, EU
There has been an increase in diseases caused by airborne infections such as influenza A/H1N1 or SARS in the recent years. Airborne infection isolation rooms are commonly used to limit the spread of airborne infections.
Harsem Trond Thorgeir, Venås Bård, Vikan Anders Welde, Lind Merethe Cecilie, Kalliomäki Petri, Koskela Hannu, EU
Ventilation and healthy classes are a recurring problem. Continuously increasing the air flow rate improves the living environment, but is unacceptable in terms of higher costs and energy loss, which is why a different approach is needed.
Paul De Schepper, EU
The interest in phase change materials (PCMs) as a solution for thermal energy storage has been growing for the last decades. It is clear that PCMs are promising for reducing the summer heat peaks without increasing the energy demand for cooling.
Timea Béjat, Emile Fulcheri, Didier Therme, Etienne Wurtz, Pierrick Péchambert, EU
Balanced ventilation units are well known to provide a sufficient amount of fresh air in residential buildings in a controlled way, without relying on ever-changing naturally driven forces.
Bart Cremers, EU
As one of the founding partners of the IEQ-GA, the networking with other organisations within the global alliance is for AIVC very important.  
Peter Wouters, EU
This workshop session will consist of a series of presentations by members of the Board for the Indoor Environmental Quality – Global Alliance (IEQ-GA).
Donald Weekes, EU
Use of Demand Controlled ventilation (DCV) can potentially save more than 50% of energy use for ventilation purposes compared to constant air volume (CAV) ventilation.
Kari Thunshelle, Thea Marie Danielsen, Sverre Holøs, Mads Mysen, EU
By the end of 2020 all newly constructed buildings have to be nearly zero energy buildings (nZEB). In school and office buildings the ventilation system has a large contribution to the total energy use.
Bart Merema, Hilde Breesch, Dirk Saelens, EU
The work reported in this paper extends previous work on the feasibility to characterise air leakage and mechanical ventilation avoiding intrusiveness of traditional measurement techniques.
Antonio Javier Alonso Sergio Castaño, Manuel Pérez, María José Jiménez, EU
Mechanical ventilation systems with heat recovery are considered the most optimal systems for residential ventilation. This research focuses on decentralized ventilation which do not need any ducting.
Mathias Merckx, Giel Bruyneel, Ivan Pollet, Jelle Laverge, EU
The air renovation of a building should be controlled in order to ensure a proper level of indoor air quality while minimize heat losses. It is a crucial point for the future energy efficiency goals.
Paolo Taddeo, Joana Ortiz, Jaume Salom, Eva Lucas Segarra, Vicente Gutiérrez González, German Ramos Ruiz, Carlos Fernández Bandera, EU
This study deals with ventilation effects on measured and perceived indoor air quality (IAQ) in a demonstrator building where IAQ problems can occur.
Loubna Qabbal, Zohir Younsi, Hassane Naji, EU
Cooking can be a major source of exposure to particulate matter. Range hoods can be used to reduce odours, moisture and contaminants resulting from cooking.
Wouter Borsboom, Willem de Gids, Iain Walker, Piet Jacobs, EU
The difficulty in measuring IAQ indicators like VOCs and particles, lies in the multiplicity of the composition of these pollutants.
Laure Mouradian, EU
Conventional building management systems are costly to install in existing buildings. Building services fail, which results in a cascade of incorrect responses, or occupants and administrators misuse systems.
Christian A. Hviid, Anders Struck, Kevin Michael Smith, EU

Pages