We have analysed the steady wind model error based on a simplified building model with one leak on the windward side and one on the leeward side of the building. Our model gives an analytical expression of this error that depends on the leakage distribution and pressure coefficients. Using a test pressure of 50 Pa in this model, standard measurement protocol constraints contain the steady wind model error within about 3% and 11% with wind speeds below 6 m s-1 and 10 m s-1, respectively. At 10 Pa, the error is in the range of 35% and 60% at 6 m s-1 and 10 m s-1, respectively. The results are very sensitive to the leakage distribution at the low pressure point. Averaging pressurization and depressurization test results may be more or less beneficial depending on the leakage distribution, pressure coefficients and test pressure.
Model error due to steady wind in building pressurization tests
Year:
2014
Bibliographic info:
35th AIVC Conference " Ventilation and airtightness in transforming the building stock to high performance", Poznań, Poland, 24-25 September 2014