Reports a case study dealing with the relation between ventilating and airing behaviour and the outside climate. Also the significance of other variables such as preferences with respect to the indoor climate are considered. Wind speed is found to correlate, but outside temperature (varying from -3 to +9 degrees C) does not correlate with the length of time the windows in the bedrooms and bathrooms are opened. Rainfall and sunshine also seem to have some influence. The main reasons for airing are that the bedrooms are too warm and not fresh.
Ventilation requirements for the reduction of humidity. Required air change rates for hygiene and moisture removal for various rooms are given. Air flow rates are calculated for natural ventilation with closed windows, hopper windows and controlled ventilation. Ventilation by window opening is discussed. Gives examples of the transfer of moisture within a building, and the main reasons for ventilation, with particular emphasis on moisture removal. Lists danger of condensation on various building elements, causes and remedies. Advises on ventilation measures.
Discusses how air flow in a building is affected by the position of the ventilation openings in the outside wall. Treats factors determining selection of controlled ventilation system and provides examples of systems available: small air vents, mechanical ventilation with acoustic and thermal insulation, ventilation with heat recovery, etc. Discusses an optimal solution with air quality control.
It is necessary to design the ventilation system to avoid excess humidity in the apartments. Discusses the sources of moisture release in rooms, properties of air temperatures in relation to moisture absorption, condensation in bedrooms in particular, and moisture damage to building fabric. Advises on ventilation measures to control humidity.
Studies the daily behaviour with respect to heating, use of windows and ventilation in newly built identical houses in Oosterhout, Netherlands. The houses have external walls of brick with cavity insulation, double-glazed windows and natural ventilation, with a gas burner furnace in the loft for heating and hot water. 57 occupants were interviewed and 41 filled in hourly log-books during 14 days recording people at home, thermostat setting, periods of open windows and trickle ventilators in the different rooms, use of radiator valves and position of doors inside the house.
This paper reports a case study dealing with the relation between ventilating and airing behaviour and the outside climate. Also the significance of other variables such as preferences with respect to the indoor climate are considered. An indication is found that wind speed correlates, but outside temperature (varying from -3 to +9 degrees C) does not correlate with the length of time the windows in the bedrooms and bathrooms are opened. Rainfall and sunshine also seem to have some influence. The main reason for airing is the opinion that the bedrooms are too warm and not fresh.
Roof space ventilation is necessary to evacuate water vapour to avoid condensation and to conserve the wooden roof supports. It has been affected by 1. increased insulation, 2. snow screens fitted under the roof, 3. increased humidity due to
Using meteorological and physical data, a model simulating pressure and air mass flow distribution in buildings was produced using the method of non-linear networks. It was used to study wind and buoyancy effects on mechanically ventilated buildings. Contents include: natural ventilation in high rise buildings with and without air-handling equipment, a study of a hospital, and calculation of the annual heat load for ventilation.
Investigates the generation of pollutants from unvented convective and radiant kerosene heaters in a residence over a 3 month period. The measured concentrations of carbon monoxide were low. However, under the conditions of use which were studied concentrations of SO2, NO, NO2, and CO2 reached or exceeded levels recommended for indoor air. Further, it was demonstrated that using a semi-open door to provide ventilation did not reduce concentrations of pollutants to acceptable levels.