AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

The AIVC website includes a protected content feature that provides access to AIRBASE. Access to the protected content is free of charge but requires you to register first.


 
Simplified, physical models for calculating infiltration in a single zone, usually calculate the air flows from the natural driving forces separately and then combine them.
Sherman M
Air infiltration and ventilation has a profound influence on both the internal environment and on the energy needs of buildings.
Parekh A, Ruest K, Jacobs M
Conventionally used thermal anemometers are able to measure velocity, but cannot determine direction.
Steimle F, Eser U, Schadlich S
Once the flow-pressurization characteristics of a building are known, the largest uncertainty in predicting air infiltration is the effect of wind shelter from nearby buildings.
Wilson D, Walker I
The possibility of unacceptable internal air pollution levels can cause concern at the design stage given the potential for cross contamination between building exhausts and ventilation intakes is there.
Perera E, Tull R, White M, Walker R R
Tracer gas tests were conducted on a five-storey apartment building to determine the air and contaminant flow patterns within the building.
Shaw C, Reardon J, Said M, Magee R
The passive perfluorocarbon method (PFT-method) has been successfully applied in ventilation measurements in rooms. The method is, in principle, also applicable to air flow measurements in ventilation ducts.
Sateri J
The methods available for the measurement of air infiltration and air movement in large industrial halls are restricted by the size of the building and the nature of the operations which take place within it.
Sutcliffe H, Waters J
This article discusses the application of tracer gas methods to industrial hygiene investigations.
Grot R, Lagus P
This report describes tracer gas measurements of the local mean age of air at different locations within an office room.
White M, Walker R
A "HESCO"-type diffuser was selected as an example for the validation exercise in the IEA Annex 20 project (Air flow pattern within buildings). It consists of 84 small round nozzles that are arranged in four rows in an area of 0.71 m x 0.17 m.
Chen Q, Moser A
A new handbook, describing in details the measurement techniques which could be used to better understand the infiltration and ventilation in buildings is presented.
Roulet C-A, Vandaele L
Airflow rates are directly affected by the amount of open area and consequently by the inhabitant behavior with respect to window opening.
Roulet C-A, Scartezzini J,Cretton P, Fritsch R
Increasing interest is attributed to the problem of the accumulation of organic vapours emitted from indoor building materials due to an effective insulation of buildings with low ventilation rates.
Gehrig R, Affolter M, Hofer P
Within the frame of the IEA Annex 20, laboratory and numerical experiments were conducted in order to study the flow within an isothermal parallepipedic testroom (L x W x H = 4.2 m x 3.6 m x 2.5 m).
Biolley F, Fontaine J, Rapp R, Serieys J
Is it possible to translate a computed flow field to a design case with different physical dimension?
Moser A
The work in this paper contributes to the work in the IEA - Annex 20 "Air Flow Patterns within Buildings" and presents a series of full-scale measurements of the concentration distribution in a room with isothermal mixing ventilation.
Heiselberg P, Bergsoe N
Seen from the AIVC Technotes 21 and 28, Ventilation Efficiency is still a complex concept. As well for measurements as for simulations.
Haghighat F, Bienfait D, Phaff H
The measurements reported in this paper were carried out in a mock up of an office room, ventilated by a commercial supply air terminal consisting of 84 nozzles (characteristic dimension SqRoot of As = 0.0975 m).
Sandberg M, Blomquist C, Mattson M
Zonal models are a promising way to predict air movement, in a room with respect to comfort conditions and gradient of temperature, because they require extremely low computer time and may be therefore rather easily included in multizone air movem
Inard C, Buty D