Multi-zone demand-controlled ventilation in residential buildings: An experimental case study

Arefeh Hesaraki, Jonn Are Myhren, Sture Holmberg, 2014
demand-controlled ventilation | indoor air quality | energy consumption
Bibliographic info: 35th AIVC Conference " Ventilation and airtightness in transforming the building stock to high performance", Poznań, Poland, 24-25 September 2014
Languages: English

Numerous studies have investigated the application of multi-zone demand-controlled ventilation for office buildings. However, although Swedish regulations allow ventilation rates in residential buildings to be decreased by 70 % during non-occupancy, this system is not very common in the sector. The main focus of the present study was to experimentally investigate the indoor air quality and energy consumption when using multi-zone demand-controlled ventilation in a residential building. The building studied was located in Borlänge, Sweden. This building was recently renovated with better windows with low U values, together with internally-added insulation materials. The building had natural ventilation, which decreased significantly after retrofitting and resulted in poor indoor air quality. Therefore, a controllable mechanical ventilation system was installed. The ventilation rate was controlled according to the demand in each zone of the building by CO2 concentration as an indicator of indoor air quality in habitable spaces and relative humidity and VOC level in the toilet and bathroom. The study showed that multi-zone demand-controlled ventilation significantly reduced the CO2 concentration leading to improvement in indoor air quality. However, building with demand-controlled ventilation consumed more energy than natural ventilation as it increases the ventilation loss by forcing more air into the building. Nevertheless, in the demand-controlled ventilation system, the energy consumption for the ventilation fan and ventilation loss was almost half of the constant high rate ventilation flow.


Related publications

This report summarizes the work of the initial working phase of IEA ECB Annex 62 Ventil
Maria Kolokotroni, Per Heiselberg, Lorenzo Pagliano, Jie Han, Regina Bokel, Peter Holzer, Annamaria Belleri, Denmark
This summary report presents insights on recommendations into how ventilative cooling i
Christoffer Plesner, Flourentzos Flourentzou, Guoqiang Zhang, Hilde Breesch, Per Heiselberg, Michal Pomianowski, Peter Holzer, Maria Kolokotroni, Annamaria Belleri, Denmark
Overheating in buildings is an emerging challenge at the design stage and during operat
Peter Holzer, Theofanis Psomas, Denmark