Haugen T
Year:
1985
Bibliographic info:
Proceedings of the CLIMA 2000 World Congress on Heating, Ventilating and Air-Conditioning, Copenhagen, 25-30 August 1985. Edited by P O Fanger. Vol 5. Solar energy - active and passive systems. p227-233. 1 fig, 1 tab, 4 refs.

The air exchange rate and total heat loss were measured in 11 detached dwellings to find the relationship between measured and calculated transmission heat loss factors based on standard Norwegian calculation methods. For 9 houses the measurements were done under stable climatic conditions. Air change rate varied between 0.2 and 0.7 ach with an average value of 0.45 ach. These measurements, together with several others, confirm that the Norwegian Standard (NS3031) for calculation of the transmission heat losses is reasonably correct.