Comparison of different airtightness and air exchange rate measurements in very small test building

S. Gendelis, A. Jakovičs, A. Nitijevskis and J. Ratnieks, 2013
airtightness | airtight sealing | air exchange | tracer gas | test buildings
Bibliographic info: Proceedings of the 34th AIVC - 3rd TightVent - 2nd Cool Roofs' - 1st venticool Conference , 25-26 September, Athens 2013
Languages: English

The airtightness of the building envelope was studied in field measurements in recently constructed experimental small test buildings. Two types of research studies were carried out: the effect of special air tight sealing and the experimental determination of air exchange rate (h-1) under real operating conditions. In very small buildings with many joints between materials and construction the role of the air tight sealing is very important; the experiments show changes in measured air tightness. Another parameter – air exchange rate has been studied in different test buildings using tracer gas equipment. Results obtained from this research show the real amount of exchanged air and it is very important to evaluate ventilation heat losses for low energy buildings.

Related publications

Setting sustainable urban development goals and developing energy efficient solutions f
INIVE eeig,
AIVC Literature List 35 is linked to the topics of “building & ductwork airtightnes
AIVC,
Setting sustainable urban development goals and developing energy efficient solutions f
INIVE eeig,