Ventilation measurement using spot sampling of sulphur hexafluoride on a solid absorbent

Describes the technique employed, including the mathematical model as well as results from a validation test using an experimental chamber. The model assumes an exponential decay of the tracer gas concentration. The precision of the analytical procedure is estimated at better than 9%, while the error of the measured ventilation rate of the test chamber was 5%.

Patterns in heating and ventilation behaviour of occupants of newly-built terraced houses.

Studies the daily behaviour with respect to heating, use of windows and ventilation in newly built identical houses in Oosterhout, Netherlands. The houses have external walls of brick with cavity insulation, double-glazed windows and natural ventilation, with a gas burner furnace in the loft for heating and hot water. 57 occupants were interviewed and 41 filled in hourly log-books during 14 days recording people at home, thermostat setting, periods of open windows and trickle ventilators in the different rooms, use of radiator valves and position of doors inside the house.

The multi-chamber theory reconsidered from the viewpoint of air quality studies.

A general multi-chamber model is presented and explored from the viewpoint of air quality studies. The model involves the following key concepts: purging flow rate and age distribution of both air and contaminants. From the physical and mathematical properties of the model, are deduced estimates of themagnitude of, and the relations between, the key concepts. The practical use of the model is illustrated.

Air intake arrangements of the supply air window from the view of comfort and ventilation efficiency.

Research was undertaken to provide buildings equipped with mechanical exhaust ventilation systems or natural ventilation with reasonable draught-free efficient ventilation. One possible solution for existing detached houses and multi-storey residential buildings is a supply air window. Recent research in Finland shows that, for the best method, about 6.0 dm3/s of outdoor air per light area m2 can be taken in through the wooden construction double-paned window without draught. The incoming air was heated to about 50% of thetemperature difference between the inner and outer air.

The measurement of ventilation parameters by means of tracer gas techniques and a microcomputer.

A tracer method was developed for the evaluation of workplace ventilation. Nitrous oxide or freon was used as the tracer. The concentration of the tracer gas was measured with an infra-red analyser. The versatility of the tracer technique for industrial hygiene applications was improved by the use of a microcomputer for data calculation, display and storage. Three applications are presented: 1. determination of the capture efficiency of a local exhaust hood, 2. the evaluation of the air leakage of a room, and 3. measurement of the local ventilation rates in a large industrial plant.

Airtightness and wall construction in prefabricated Swedish single family houses, 1984.

This survey describes how external walls and joints are constructed in practice. The paper gives you an opportunity to compare how successful the implementation of airtightness has been in Sweden in comparison with the results presented in the report D2:1983 "Air infiltration control ..." by A Elmroth and P Levin. The survey covers the majority of all Swedish prefabricated single family houses constructed in 1984. All big prefabrication companies are included in the survey.

The role of air infiltration in energy conservation.

A reduction of infiltration and ventilation rates by a mere 1% would reduce annual US energy costs by about 300 million dollars. Infiltration and ventilation activities are an important part of the comprehensive energy conservation research policy of the US Department of Energy. The starting point for this policy is an analysis of how energy is used in buildings, starting with an examination of the buildings themselves. Summarizes US research and future activities.

Philosophy and background of the Dutch standard for airtightness of dwellings.

This paper discusses the situation in the Netherlands with respect to air tightness of dwellings and reflects discussions about this in the Dutch Standard Committee on Air Tightness of Buildings. Results of measurements and calculations are given and the considerations of different groups in thediscussion are included. Finally an attempt is made to produce a model for the prediction of air flow rates, infiltration losses and seasonal gas consumption on the basis of air leakage measurements.

Patterns in ventilating and airing behaviour in relatively well-insulated newly-built terraced houses.

This paper reports a case study dealing with the relation between ventilating and airing behaviour and the outside climate. Also the significance of other variables such as preferences with respect to the indoor climate are considered. An indication is found that wind speed correlates, but outside temperature (varying from -3 to +9 degrees C) does not correlate with the length of time the windows in the bedrooms and bathrooms are opened. Rainfall and sunshine also seem to have some influence. The main reason for airing is the opinion that the bedrooms are too warm and not fresh.