Some factors affecting the concentration of radon and its daughters inside houses

Plastic track detectors LR-115 and CR-39 were used to estimate the concentration of radon-222 and its daughter products (218Po, 214Po) in a room by recording tracks of their alpha-particles. Although the ventilation rate is the main factor th

Dynamic behaviour of pollutants generated by indoor combustion

When indoor air concentrations from indoor combustion processes are estimated, source strengths and ventilation rates are usually considered. Recent studies, conducted in the Energy Research House at Iowa State University, indicate that seve

Effectiveness of local ventilation in removing simulated pollution from point sources

The effectiveness of range hoods and window fans in removing indoor pollutants is considered. Tests were conducted in a two-room test space with an infiltration rate less than 0.1 hr-1 using sulphur hexafluoride as a tracer gas. Range hood te

A comparative study of the performance of general ventilation systems in evacuating contaminants

Based on the age concept, the performance of the following three principle ventilation schemes have been monitored (supply air terminal - extract air terminal), ceiling-ceiling, ceiling-floor, floor-ceiling. All systems used only air for both heating and cooling. Contaminants with both greater, less and approximately the same density as air were released at a point source. The tests were both carried out in an empty room and with a person (heated mannekin) in the room.

Air movements in buildings

The indoor air quality depends on several different factors. One is the air flow or air movements within the building and through its external walls. These flows are governed by the type of leakage openings and the pressure differences across the walls and the air terminal devices. The pressure differences are caused by wind, thermal and fan forces. Mathematical models can be used to calculate the different air flow rates. A simple example is used to demonstrate magnitude and consequences of this air leakage for two different ventilation systems.

Ventilation stratification and air mixing

Minimising ventilation for energy conservation in buildings requires that ventilation efficiency be high. The common practice of locating supply outlets and return inlets in or near the ceiling creates an opportunity for air tobypass from the supply to the return without mixing in the occupied space. Equations are derived for calculating efficiency and stratification factor from tracer gas decay measurements.

Contaminant removal performance in terms of ventilation effectiveness.

The paper shows that age analysing techniques are an excellent tool to assess ventilation effectiveness. It is important to differentiate between air exchange effectiveness and contaminant removal effectiveness, having continuous generation of contaminants. Only when a source is homogeneous andpassive, are the age of the air and the contaminants in the room equal. However, the air exchange effectiveness accounts for the removal effectiveness of the contaminant left in the room when the generation stops.

The sick building syndrome

Examines evidence for relating sickness to the office environment. Notes research into the office building syndrome (obs) in various countries. Notes that although air conditioning goes back to the 1920s, obs has been in the news only during the last five years or so. Notes the contribution to this of energy saving regulations. Notes the complex nature of indoor air contamination. Points to obvious factors such as air conditioning systems unserviced for 30 years, occupational psychology, indoor architecture, climatic constance and air ionisation.

Research report. Natural ventilation - measurement and prediction

Looks briefly at current research into developing techniques for measuring and predicting natural ventilation and infiltration rates in buildings.

Minimum ventilation rate

Notes that the information in the ASHRAE 'Fundamentals' volume on how much ventilation ought to be provided is based on work nearly 50 years old. Reports new work on permissible ventilation rates produced by H B Bouwman of the Dutch Research Institute for Environmental Hygiene of the Central Organisation for Applied Scientific Research TNO. The numerical purpose of the work was to find the rate of ventilation required to keep complaints from occupants of rooms about unacceptable smells to less than 5% or 1%.