Indoor air pollution in the Netherlands.

Reports results of studies of concentrations of carbon monoxide, nitrogen dioxide, respirable suspended particulate matter and volatile hydrocarbons in houses in the Netherlands. Carbon monoxide and nitrogen dioxide were studied in about 300 homes in Arnhem and Enschede in October-December 1980. Respirable suspended particulate matter, nitrogen dioxide and volatile hydrocarbons were measured in 175 houses in Ede in winter 1981-82. Indoor air pollution was often much higher than the common outdoor levels. In several houses existing or proposed standards for ambient air were exceeded.

Indoor carbon monoxide and nitrogen dioxide pollution in the Netherlands.

Describes the influence of gas geisers on carbon monoxide and nitrogen dioxide production in 254 houses in the Netherlands. It was shown that burner type and maintenance system were the main factors influencing the carbon monoxide levels in the flue gases. The nitrogen dioxide concentration in the kitchen was greatly influenced by the presence of a flue for the geiser and by use of a cooker hood. Associations were also found with type of space heating, use of shower and socioeconomic status of the occupants.

Indoor NOx pollution.

Discusses sources of nitrogen dioxide in indoor air in houses in the Netherlands. Measurements were made in a random sample of about 300 houses with a geiser in Enschede and Arnhem. A second sample of 326 houses in Ede were measured a year later. The Dutch outdoor standard for concentrations of nitrogen dioxide was regularly exceeded indoors.

Indoor nitrogen dioxide pollution and respiratory symptoms of school children.

The influence of indoor nitrogen dioxide exposure on respiratory symptoms of school children was investigated in a case-control study. The election method used was useful in obtaining symptomatic children, but insufficient indefining cases and controls without additional information. No relationship between indoor NO2 and respiratory symptoms was found. Bias may have been present, especially because of the high mobility of the study population. Attempts to estimate historical exposure were inaccurate.

The relationship between indoor nitrogen dioxide concentration levels and personal exposure: a pilot study.

A small, personal monitoring study was performed in a subpopulation (14 families) of a case-control study on the relationship between indoor nitrogen dioxide exposure and respiratory diseases of school children. 

Indoor NO2 pollution and personal exposure to NO2 in two areas with different outdoor NO2 pollution.

Indoor NO2 concentrations were measured in the kitchen, the living room and bedroom of 612 houses in two different areas in the Netherlands. In asub-sample, personal exposure of the housewives to NO2 was measured. NO2concentrations indoors depended on the presence or absence of (un)vented gas appliances. Personal NO2 exposure was only different between the two areas in the group with the lowest indoor concentrations. It was concluded that with respect to NO2 exposure it is impossible to categorize groups without accounting for gas appliances inside the house.

Buoyancy driven flow through an open door.

Describes use of water tanks to simulate two- and three-dimensional natural ventilation air flows through open doors and windows. Density differences are produced by dissolved salt. The technique is inexpensive and visualisation of flows through complicated patterns of doors and passageways, and even separate floors can be easily set up.

Condensation and mould growth - causes and cures.

Describes the principal causes of condensation in dwellings in the UK. Monitoring the existing environmental conditions within a building, plus a structural and tenant survey, is required to determine the correct cure. Theinstrumentation and techniques are listed, and some solutions are suggested.

Signs of recovery.

Describes evaluation of two integrated heating and ventilating systems, one a modified warm air system and the other a modified mechanical ventilation system. From the technical viewpoint the systems were found to be efficient. However it remains to be seen whether mechanical ventilation systems with heat recovery including flue heat recovery can be justified in economic terms.