A small commercial building was monitored before and after energy-saving retrofits to study the impact of retrofits upon ventilation rates, humidity, building pressure, and air-conditioning energy use. Duct airtightness testing identified severe duct leakage as a significant source of uncontrolled airflow. Differential pressure and infiltration measurements using tracer gas indicated an attic exhaust fan as another significant source of uncontrolled airflow. Duct repair resulted in a 31% drop (30.5 kWh/day) in cooling energy and an increase in relative humidity from 72% to 76%.
A simple duct system was installed in an attic test module for a large-scale climate simulator at a U. S. national laboratory. The goal of the tests and subsequent modeling was to develop an accurate method of assessing duct system performance in the laboratory, enabling limiting conditions to be imposed at will and results to be applied to residential attics with attic duct systems. Steady-state tests were done at a severe summer condition and a mild winter condition. In all tests the roof surface was heated above ambient air temperatures by infrared lights.
Previous work by Linden, Lane-Serff and Smeed (1990) has developed a simple mathematical model for natural displacement ventilation of an enclosure. The work also introduced the experimental salt-bath technique, which uses salt solutions and fresh water to generate buoyancy forces that are analogous to those found in naturally ventilated buildings. The work claims that a good correlation exists between the predictions of the simple mathematical model and the results obtained using the salt-bath technique.
This paper presents results of a study where computational fluid dynamics (CFD) was the numerical tool used to analyze the ventilation performance in stations of the Buenos Aires Metro subway system. Both natural and mechanical ventilation options were studied. The study showed that although natural ventilation was sufficient to maintain the temperature criteria, it presented a potential egress problem by letting hot gases leave through the entranceways.
This paper considers the numerical modeling of room airflows and illustrates the usefulness of computational fluid dynamics as a design tool for ventilation systems. A computer code, which simulates steady, buoyant, turbulent, three-dimensional flows in Cartesian coordinates, was developed. The time-averaged equations for conservation of mass, momentum, and energy are solved. A low Reynolds number kE model is used to simulate the turbulent transport. The code was validated by comparing it to benchmark data for both liddriven and buoyancy-driven cavity flows.
Wintertime window condensation problems were reported on the top two floors of a five-story, multi-unit residential building in central New York (7200, base 65° F heating degreedays ). Initially built as a five-story brick hotel at the turn of the century, the building was rehabbed into low-income apartments in the early 1990s. Ventilation in each unit consisted of operable windows and a single bath exhaust. Condensation on windows was severe enough to support fungal contamination in the first winter of occupancy.
Video camera calibrations and field tests for air change rates in a test house were performed to develop a new method of measuring air change rates using a video imaging technique. From the camera calibrations, it was found that good correlation was achieved between image signals and luminous reflectance of achromatic color chips by appropriately adjusting the pedestal level of the video camera so that the image signals were made equal to zero for the black level of the picture.