Containment of hazards in a laboratory chemical hood is based on the principle that air drawn through the face area of the hood is sufficient to overcome the many challenges at or near the opening. Challenges to overcome include, but are not limited to, air velocities near the hood, movement of the researcher, people walking past the hood, location of equipment inside the hood, size of the sash opening, and the shape and configuration of entrance conditions. To overcome these challenges, a sufficient face velocity must be maintained.
The heating, ventilating, and air-conditioning (HVAC) system for a laboratory must be designed with consideration for safety, air cleanliness, and space temperature. The primary safety concern is to ensure proper coordination between fume hood exhaust and makeup air supply. Air cleanliness is maintained by properly filtering supply air, by delivering adequate room air changes, and by ensuring proper pressure relationships between the laboratory and adjacent spaces. Space temperature is maintained by supplying enough cooling air to offset the amount of heat generated in the room.
Current model building codes require attic ventilation in all U.S. climates. Originally, these requirements were strictly based on concerns for condensation in attics during winter in cold climates, and they were based on limited technical information. Nevertheless, attic ventilation has become the uncontested strategy to minimize condensation and ice dams during winter and extreme attic temperatures during summer. However, other strategies exist that address each of these problems as well as or better than attic ventilation.
The goal of this work was to assess the performance of two common ventilation systems, an exhaust and an exhaust supply system, in Swedish apartment buildings. Since correct air-exchange and interzonal airflows are important for removing contaminants and improving indoor air quality, these airflows were analyzed by systematic computer calculations when selected input parameters were varied around their default values.
This paper discusses the numerical study of the effectiveness of atrium smoke exhaust systems. This study is part of a project initiated by A SH RAE and the National Research Council of Canada (NRCC), in which both physical and numerical techniques were employed to determine the effectiveness of such systems and to develop guidelines for their design. This paper presents numerical predictions obtained using a computational fluid dynamics (CFD) model and compares the numerical results with the experimental data obtained from tests performed in this project.
Canada Mortgage and Housing Corporation (CMHC) conducted a series of attic research projects from 1988to1997. Initially, there were few field test data to substantiate how attics dealt with air and moisture transfer. The CMHC research developed a test protocol for attic airtightness and air change testing and then proceeded to field testing of a variety of attics in different climatic areas. An attic model, ATTIX, was referenced against test hut data and used to simulate attic performance across Canada.
This paper discusses the development and application of standards of performance (SOPs) for HVAC&R equipment, plumbing systems, and building envelope systems in relation to maintaining acceptable indoor air quality (IAQ) in buildings. The utilization of the SOP procedure, developed in ASHRAE Research Project 853, will aid in the proper operation of systems and verify that acceptable building IAQ levels are obtained.
While monitoring the comparative performance of two test houses in Pittsburgh, Pennsylvania, it was noticed that the attic air temperature of one house with a plastic shake roof was consistently 20°F ( 11°C) cooler than its twin with asphalt shingles during peak summer cooling periods. More detailed monitoring of the temperatures on the plastic shake, the roof deck, and the attic showed this effect to be largely due to the plastic shake and not to better roof venting or other heat loss mechanisms.
This paper describes a residential research facility built for the experimental measurement of the relative energy and moisture performance of various residential building envelope components and systems. The building comprises 12 test bays on an east/west axis bounded on each end by a guard bay. The eastern six test bays are framed in steel, and the western six bays are framed in wood. Each half of the building contains a symmetrical mix of vented and unvented cathedral and attic roofing systems and is built above a heated basement.