A new thermal comfort guideline for moderate environments has been developed: the ATG guideline. The underlying method distinguishes between ‘type Alpha’ versus ‘type Beta’ buildings to provide for different adaptation effects. Type Alpha indicates buildi
This study aims at the development of an optimal design tool using a genetic algorithm (GA) andcomputational fluid dynamics (CFD). To represent a realistic building environment, random variables(fluctuating outdoor conditions), passive control variables (model variables) and active control variables (HVAC system) were set up. A combination of designs are determined based on the relationship between the fluctuating outdoor conditions and the HVAC system in the optimization inquiry.
An increasing impact of ventilation and air-conditioning to the total energy consumption of buildings has drawn attention to natural ventilation and passive cooling. The very common way of natural ventilation in residential buildings is passive stack ventilation. The passive stack ventilation relies on the stack effect created by the temperature difference between air temperature inside and outside a building.
The paper describes the development of unsteady pulse pressurisation techniques for measuring the leakage of buildings. The original version of the technique (the UP technique) has been investigated experimentally and theoretically in a single cell test space. The initial results are very promising, with a good degree of repeatability and similar sensitivity to changes in leakage levels as the conventional steady (DC) technique. An interesting outcome of these early tests was the observation that quasi-steady flow could be established in a short time.
Fan-pressurisation method was used to test the air infiltration rate of 191 dwellings in England. All tested homes were either pre or post the introduction of energy efficient retrofit measures such as cavity wall insulation, loft insulation, draught stripping and energy efficient heating system. Results show that the average air infiltration rate of the post dwellings is only marginally lower by 4% compared to the pre dwellings.
The hygrothermal behavior of the building envelope affects the overall performance of a building. There are numerous tools for the simulation of the heat and moisture transfer in the building envelope and also whole building simulation tools for energy calculations.
This paper contains a numerical study of the indoor temperature, humidity, and comfort and indoor air quality conditions in a bedroom located in Saint Hubert, Belgium. The performance of the bedroom is presented for a range of constant outdoor ventilation rates (0.1 ach to 1 ach) with and
The humidity of rooms and the moisture conditions of materials in the enclosure of buildings depend much on each other because of the moisture exchange that takes place over the interior surfaces. These moisture influences also depend strongly on the thermal conditions of indoor spaces and enclosure elements of buildings. In turn, the moisture and humidity conditions have significant impact on how buildings are operated.
The Delta-Q duct leakage test has been developed over the past several years as an improvement to existing duct pressurization tests. It focuses on measuring the air leakage flows to outside at operating conditions that are required for energy loss calculations for duct systems, and infiltration impacts. The Delta-Q test builds on the standard envelope tightness measurement technique of a blower door by repeating the tests with the system air handler off and on. This study uses detailed