Airtightness - measurement and measurement methods Matningar och matmetoder for lufttathet

Describes methods of measuring the air tightness of whole buildings. Outlines three tracer gas methods; constant concentration; decreasing concentration and constant emission. Describes pressurisation method. Describes measuring equipment and test procedure and discusses calculation of ventilation rateand error magnitudes. Gives brief summary of measured results and an appendix contains a print-out of data on the airtightness of houses.

Ventilation of rooms due to wind forces and energy consumption for the ventilation. Die Durchluftung und der Warmebedarf fur die Luftung.

Briefly discusses wind-pressure on buildings. Derives equations for air-flow in a building without internal walls caused by wind pressure from perpendicular and oblique wind. Gives simplified method for calculating air flows inside a building with internal walls. Gives tables showing results of calculation of air flows for a building with two and three rooms. Discusses more complicated building types and gives results of calculation. Outlines determination of ventilation heat loss, air leakage of windows and doors.