Indoor air quality in primary schools.

The objective of this paper was to verify that problem of indoor air pollution is present in primary school in Yugoslavia. Indoor air pollutant levels of sulfur-dioxide, soot, nitrogen dioxide, carbon monoxide and formaldehyde, and air-microflora was determined in different places of school environment. The average indoor level of sulphur dioxide and soot in primary schools were comparatively high. Determined average levels of carbon monoxide were from 13 .2 - 31. 8 mg/m3, levels of nitrogen dioxide were 20 - 62 μg/m3 and levels of formaldehyde: 0.01 - 0.83 μg/m3.

Airborne particulate matter within 100 randomly selected office buildings in the United States (base).

The United States Environmental Protection Agency (EPA) has collected extensive indoor air quality data in 100 randomly selected office buildings following a standardized protocol developed for the Building Assessment Survey and Evaluation (BASE) study. These data were collected to provide normative data in typical office buildings for various uses including: a) basis for making policy and guidance development; b) hypothesis development and testing; c) input into risk assessments and environmental models; and, d) comparison of complaint buildings to "typical" building stock.

Wind towers and wind driven ventilation.

Passive cooling techniques driven purely by natural wind forces present a highly attractive environmental solution in the perspective of low energy architecture. The physics governing passive cooling are well understood and have been extensively discussed in the literature. Indeed the necessary design details that must be incorporated to achieve the full potential of the technique, such as exposed thermal massive and good internal and solar gain control, are also well understood.

Assessment of health risks by air conditioning systems in a printing office.

Repeated measurements were taken in a printers' office where one case of humidifier lung disease had occurred. In water supplies of the office's air conditioning systems, the number of moulds was mainly below 50 colony-forming units (CFU)/mL, the quantity of anaerobic bacteria mostly below 10,000 CFU/mL. Twenty-nine out of the 120 participating employees complained of symptoms such as dyspnea, cough, malaise whose majority was not associated with the workplace. Twenty-eight had IgG antibodies to humidifier antigens prepared from water supplies of the air conditioning systems.

Moisture damage in schools - symptoms and indoor air microbes.

The association of moisture damages of school buildings with microbial indoor air quality and health status of school children was studied. To determine the association the school buildings (N=32) were divided into the moisture damaged (index) and non-damaged (reference) schools according to technical inspection data. Children's health surveys were made by questionnaires. Microbes were determined from indoor air of school buildings using a six-stage impactor. Children in the index schools reported more respiratory symptoms compared to children in the reference schools.

The measurement of indoor environmental parameters in a newly started and refurbished school.

The aim of the study was to follow changes in allergens and airborne particles in the indoor environment during the first year in a newly started school. The building is from the sixties and was refurbished during the summer to be made suitable as a school. New internal walls and some new flooring were installed, and walls and ceilings were redecorated. Most of the furniture, textiles and lamps are new. Samples for allergen determination were collected by sampling settled dust with a vacuum cleaner. Airborne allergens were collected by a newly developed method involving an ionisator.