Snapshots of shading options.

                

Inferring ventilation and moisture release rates from field psychrometric data only using system identification techniques.

System identification techniques are developed allowing room or building ventilation and moisture release rates to be inferred from field psychrometric data only. The techniques have been developed primarily to allow the surveying of a large number of houses so that statistical properties can be compiled, in which high accuracy of individual results is not required. This system provides an alternative to PFT tubes, with some economic advantages.

On the performance of radiant barriers in combination with different attic insulation levels.

Experiments and computer simulations were conducted to evaluate the performance of radiant barriers under three different insulation levels in residential applications. The experiments were conducted in central Texas, USA using side-by-side comparisons in which two houses, with identical floor plans and thermal profiles, were used. The houses were instrumented, calibrated, and their heat transfer rates across the ceilings were measured and recorded. A heat and mass transfer model was used to run the computer simulations.

Space conditioning using evaporative cooling for summers in Delhi.

The article examines the possibility of space conditioning the interiors of a multistorey office building in Delhi using evaporative cooling in the summer months of April, May and June. The temperature and humidity conditions obtained in a room of the building with direct evaporative cooling are studied by simulation. In this case study, the room is assumed to have a south-facing wall with a window and all other walls, ceiling and floor are interior partitions.

Reexamining roof ventilation.

              

Moisture conditions of outdoor air ventilated crawl spaces in apartment buildings in a cold climate.

The effects of air change and ground covers on crawl space moisture balance in a cold climate are discussed in this paper. The objectives were to assess the suitability of outdoor air-ventilation in the crawl spaces of apartment buildings, to determine the optimum air change rate with and without ground covers, and the effect of the ground covers' thermal insulation on moisture behaviour. Measured data from the test building was used to develop the crawl space model in a modular simulation environment, where the parametric simulations were carried out.

Volatile organic compound concentrations and emission rates in new manufactured and site-built houses.

Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-9.5 months following installation and in seven new site-built houses 1-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied. Ventilation rates ranged from 0.14-0.78 h-1. Several of the sitebuilt houses had ventilation rates below the ASHRAE recommended value.

A survey of exposure to Diesel engine exhaust emissions in the workplace.

Forty sites were visited during a survey of exposures to diesel engine exhaust emissions. Personal and background exposure to gaseous components, respirable dust, elemental carbon, organic carbon and total carbon were measured and details of control systems were recorded. The results show a wide spread in exposure patterns reflecting the different work practices, job categories of employees and the control methods used. However, sites where fork-lift trucks were in use consistently produced the highest exposures.