Join Our Webinar on Energy-Efficient Ventilation Systems!

The Air Infiltration and Ventilation Centre (AIVC) invites you to register for the upcoming webinar, "New Developments in Design and Characterisation of Energy-Efficient Ventilation Systems." This event will take place on June 20th, 2024, from 15:00 to 16:30 CET.

Participation is free, but prior registration is required.

English

Suitability of Low-Cost Particulate Matter Sensors for Measurements in Ventilation Systems

Particulate matter (PM) is one of the most critical pollutants affecting indoor air quality (IAQ). Hence, reducing the exposure of occupants to indoor PM pollution is critical. Ventilation systems for commercial and residential buildings are instrumental for achieving this goal.

Analysis of Potential Impacts of Policy Options for Inspections of Stand-alone Ventilation Systems in EU Dwellings

Various field studies have shown that in a vast majority of European countries the quality of installed residential ventilation systems is poor, with a large proportion of systems having significantly lower installed flow rates than the required values, or having poor energy performance due to flaws in design, installation or operation. This paper analyses the potential impact of different policy options for an EU-level approach for inspection of stand-alone ventilation systems in residential buildings until 2050.

Analysis of Zoned Residential Ventilation Systems

Trends in home heating and cooling in the US are resulting in less mixing of air within dwellings, either due to not using central forced air systems, or to reduced loads and runtimes in high performance homes. This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model of new California dwellings, including a 1-story single-family dwelling and a single apartment unit. Zoned and unzoned ventilation systems were simulated for exhaust, supply and balanced fan types.

Air Distribution Assessment - Ventilation Systems with Different Types of Linear Diffusers

The primary purpose of ventilation and air-conditioning system is to ensure internal comfort conditions through a continuous supply of air and maintaining the assumed indoor parameters. High air velocity in the occupied zone may result in an uncomfortable feeling of the draft, cooling effect, or local discomfort. The subjects of the study are linear diffusers, which depending on the purpose, are installed in ceilings, floors, or walls. Models may vary widely in their shape, number or size of slots/nozzles, and the length or shape of the deflector blades.

Airtight Buildings, Thermography and Ventilation Systems in Practice

The book of proceedings of the 13th International BUILDAIR Symposium "Airtight Buildings, Thermography and Ventilation Systems in Practice",  held on June 2-3  2023 in Hannover, Germany. Contains 36 abstracts.

Measuring airtightness of 100-meter high-rise buildings (lessons learned) – part 2

Worldwide, the demand for airtightness tests of tall buildings with a height of approximately 100 m is increasing. This report provides information on the planning and measurement concept for testing the entire building as a “single-zone” and presents the results and findings of the airtightness tests. The test set-up and the tests as such...

Messung der Luftdichtheit von Hochhäusern über 100 Meter (Projekterfahrungen) – Teil 2

Weltweit steigt die Nachfrage nach Luftdichtheitsprüfungen von hohen Gebäuden mit einer Höhe ab ca. 100 m. Dieser Bericht informiert über das Planungs- und Messkonzept zur Prüfung des gesamten Gebäudes als „Single-Zone“ und stellt die Ergebnisse und Erkenntnisse der Luftdichtheitsprüfungen vor. Der Prüfaufbau und die Prüfungen...

Zone measurements and their analysis as carried out in apartments

According to the two Swiss building standards Minergie-P and Minergie-A, individual dwelling units are considered measuring zones for airtightness, irrespective of whether they are in a new, renovated or modernized building. The Minergie standards focus on comfort between the dwelling units and the energy losses...

Auswertung von Zonenmessungen am Beispiel von Wohnungen

Für die beiden schweizerischen Energiestandards Minergie-P und Minergie-A werden bei der Luftdichtheit die einzelnen Nutzeinheiten als Messzonen betrachtet, egal ob Neubau oder Erneuerung / Modernisierung. Im Vordergrund steht der Komfort zwischen den Nutzungseinheiten nebst den energetischen Verlusten durch Infiltration...