Energy conservation by regulation of the central mechanical ventilation system in high rise buildings: realistic or not?

The investigation was divided into several parts: 1, measurements of a mechanical ventilation system, 2, calculation model for this system, 3, measurements of the air leakage of the facades of a flat and 4, calculation model for this flat.

Occupant behaviour with respect to ventilation. Final Report. Comportement energetique des usagers en matiere d'aeration. Rapport final.

Discusses reasons behind occupant ventilating behaviour, such as: 1. general attitudes, particularly regarding energy, 2. occupant requirements, 3. components of the habitat micro-climate, 4. optimum micro-climate and desired micro-climate, 5. means available in the habitat to modify the micro-climate - a. general means, b. ventilation as a specific means, 6. balancing requirements against means, 7.

Patterns in ventilating and airing behaviour in relatively well-insulated newly-built terraced houses. Het ventilatie- en luchtgedrag in relatief goed getsoleerde nieuwbouwwoningen motieven en consequenties voor het energieverbruik.

Reports a case study dealing with the relation between ventilating and airing behaviour and the outside climate. Also the significance of other variables such as preferences with respect to the indoor climate are considered. Wind speed is found to correlate, but outside temperature (varying from -3 to +9 degrees C) does not correlate with the length of time the windows in the bedrooms and bathrooms are opened. Rainfall and sunshine also seem to have some influence. The main reasons for airing are that the bedrooms are too warm and not fresh.

Residential indoor air quality, structural leakage and occupant activities for 50 Wisconsin homes.

As part of an investigation into the influence of a residential weatherization program on indoor air quality and energy efficiency, a multi-pollutant survey of the air inside 50 Wisconsin homes was conducted three times during the heating season

Patterns in heating and ventilation behaviour of occupants of newly-built terraced houses.

Studies the daily behaviour with respect to heating, use of windows and ventilation in newly built identical houses in Oosterhout, Netherlands. The houses have external walls of brick with cavity insulation, double-glazed windows and natural ventilation, with a gas burner furnace in the loft for heating and hot water. 57 occupants were interviewed and 41 filled in hourly log-books during 14 days recording people at home, thermostat setting, periods of open windows and trickle ventilators in the different rooms, use of radiator valves and position of doors inside the house.

Patterns in ventilating and airing behaviour in relatively well-insulated newly-built terraced houses.

This paper reports a case study dealing with the relation between ventilating and airing behaviour and the outside climate. Also the significance of other variables such as preferences with respect to the indoor climate are considered. An indication is found that wind speed correlates, but outside temperature (varying from -3 to +9 degrees C) does not correlate with the length of time the windows in the bedrooms and bathrooms are opened. Rainfall and sunshine also seem to have some influence. The main reason for airing is the opinion that the bedrooms are too warm and not fresh.

Multi-chamber air renewal survey using constant concentration tracer-gas technique. Mesures du taux de renouvellement d'air a l'aide d'un dispositif compact a concentration constante.

An accurate determination of air renewal rate and connective exchanges between units was needed for study of the solar units of the experimental building LESO, in both an occupied and empty state. The CESAR compact equipment for tracer gas (nitrous oxide) measurement was developed. This unit uses a microcomputer to perform a simultaneous and periodical gas analysis in 10 locations. Three tracer gas methods can be used: decay, constant concentration, and continuous flow. The device and regulating program work well with low rates of concentration (100ppm of nitrous oxide).

Energy performance standards regarding air infiltration of buildings in Switzerland.

The Swiss performance standard for energy conservation in buildings SIA 380/1 is explained. This standard leaves air infiltration and other detail decisions to planners if minimum performance levels are met. Calculation procedures for heat balances based on a standard occupancy are described. Tools to achieve optimum space heating and ventilation rates are explained. Instrumentation for checking the thermal performance of the house in operation is defined.

Stability of body odour in enclosed spaces

Sedentary subjects occupied an environmental chamber (20-22 deg C, 35-50% RH) with low ventilation for 90 min. Judges (visitors) evaluated the odour of the chamber before and during, and after the 90-min period of occupancy. Odour intensity increased throughout occupancy and decayed afterwards. However, therate of decay exceeded that anticipated from ventilation rate alone. The results implied that body odour is unstable with a half-life of 55 min. This instability will influence quantitative requirements for ventilation during nonsmoking occupancy.

Air quality measurements in low leakage houses

Results of air quality measurements are presented for a group of low-leakage houses located in Saskatoon, Saskatchewan. A total of 46 houses were tested for formaldehyde, nitrogen dioxide, radon, and humidity levels. The median level of formalde