Continuous monitoring in occupied residences of air contaminants from unvented combustion sources

Continuous monitoring of NO, NO2, CO, CO2, and O2 depletion was conducted in 14 residences (13 with kerosene space heaters and one without) in two locations in the residence (room with the heater and bedroom) and outdoors. The continuous monitor

Characterization of residential air pollution from unvented kerosene heaters

Investigates the generation of pollutants from unvented convective and radiant kerosene heaters in a residence over a 3 month period. The measured concentrations of carbon monoxide were low. However, under the conditions of use which were studied concentrations of SO2, NO, NO2, and CO2 reached or exceeded levels recommended for indoor air. Further, it was demonstrated that using a semi-open door to provide ventilation did not reduce concentrations of pollutants to acceptable levels.

An investigation of operational factors that influence emission rates from gas appliances

Reports the result of investigation of the impact of various operational factors on trace combustion products emission rates from unvented gas appliances including ranges and space heaters. The impact of the following factors on the indoor NO, NO2 and CO emission rates were evaluated under controlled conditions in an environmental chamber - 1) the appliance typeand/or design, 2) the primary aeration level, 3) the fuel input rate, 4) the time dependence of emission rates, and 5) the presence of absorbing surfaces such as wood, plaster board, curtains, carpets, linoleum and plaster.

Modeling and measurement of pollutants inside houses in Pittsburgh, Pennsylvania

Mathematical models for predicting indoor pollutant levels are being developed and compared with measured concentration in three residential dwellings - a relatively new townhouse constructed according to rigid energy-conservation guidelines,

Equipment for personal and portable air monitoring - A state-of-the-art survey and review

The Harvard School of Public Health and the Energy and Environmental Policy Centre of the Kennedy School of Government, under the auspices of the Electric Power Research Institute and the Gas Research Institute, conducted a"Workshop on Evalu

Multivariate model for predicting NO2 levels in residences based upon sources and source use

Diffusion-type passive monitors were placed for a two-week period in each of 303 residences in the New Haven (Conn.) area during a 12 week sampling period January to April 1983. For each home NO2 levels were recorded outdoors, and in three ro

Air quality measurements in low leakage houses

Results of air quality measurements are presented for a group of low-leakage houses located in Saskatoon, Saskatchewan. A total of 46 houses were tested for formaldehyde, nitrogen dioxide, radon, and humidity levels. The median level of formalde

Midway house-tightening project: a study of indoor air quality.

Describes a study of indoor air quality in 12 retrofitted houses of the Bonneville Power Administration (BPA) Midway Substation Residential Community, undertaken by LBL and BPA. Measures effective leakage areas and average concentrations of nitrogen dioxide, formaldehyde and radon before and after retrofit. Finds average reduction in leakage area of 32%. None of the pollutants measured before or after retrofit reached levels exceeding existing guidelines.

Air pollution in dwellings. Luchtverontreiniging in woningen.

Reviews sources of indoor air pollution, factors which influence pollutant concentration, and health aspects. Reports on investigations into carbon monoxide concentrations in kitchens with geysers. Treats various factors including geyser type, state of maintenance, frequency of use, occupant type, cooking and ventilating behaviour, time and location of measurements etc.Reports nitrogen dioxide concentration measurements in kitchens and livingrooms relating to cooking and smoking.

The airtightness of a sound-proof dwelling house and its ventilation plan.

Reports investigation of the air quality in a sound-insulated dwelling house. Measurements of ventilation rate and concentrations of CO, CO2, and NO2 were measured in a tight sound-insulated dining-kitchen, with and without the operation of a gas range, instantaneous hot-water heater and ventilation fan. Finds that natural ventilation was inadequate when the gas appliances were operating and recommends that an instantaneous gas hot-water heater should be provided with an exclusive air exhauster.

Pages