The importance of reducing adventitious infiltration in order to save energy is highlighted by the relevant building standards of many countries. This operational infiltration is often inferred via the measurement of the air leakage rate at a pressure differential of 50 Pascals. Some building codes, such as the UK’s Standard Assessment Procedure, assume a simple relationship between the air leakage rate and mean infiltration rate during the heating season, the so-called leakage-infiltration ratio, which is scaled to account for the physical and environmental properties of a dwelling. The
Most dwellings in the United States are ventilated primarily through leaks in the building shell (i.e., infiltration) rather than by whole-house mechanical ventilation systems. Consequently, quantification of envelope air-tightness is critical to determining how much energy is being lost through infiltration and how much infiltration is contributing toward ventilation requirements. Envelope air tightness and air leakage can be determined from fan pressurization measurements with a blower door. Tens of thousands of unique fan pressurization measurements have been made of U.S.
The air leakage of a building envelope can be determined from fan pressurization measurements with a blower door. More than 70,000 air leakage measurements have been compiled into a database. In addition to air leakage, the database includes other important characteristics of the dwellings tested, such as floor area, year built, and location. There are also data for some houses on the presence of heating ducts, and floor/basement construction type. The purpose of this work is to identify house characteristics that can be used to predict air leakage.
Explicit algebraic equations for calculation of wind and stack driven ventilation were developed by parametrically matching exact solutions to the flow equations for building envelopes. These separate wind and stack effect flow calculation procedures were incorporated in a simple natural ventilation model, AIM- 2, with empirical functions for superposition of wind and stack effect and for estimating wind shelter.
Infiltration has traditionally been assumed to contribute to the energy load of a building by an amount equal to the product of the infiltration flow rate and the enthalpy difference between inside and outside. Application of such a simple formula may produce an unreasonably high contribution because of heat recovery within the building envelope. Previous laboratory and simulation research has indicated that such heat transfer between the infiltrating air and walls may be substantial.
The role of ventilation in the housing stock is to provide fresh air and to dilute internally-generated pollutants in order to assure adequate indoor air quality. Blower doors are used to measure the air tightness and air leakage of building envelopes. As existing dwellings in the United States are ventilated primarily through leaks in the building shell (i.e., infiltration) rather than by whole-house mechanical ventilation systems, accurate understanding of the uses of blowerdoor data is critical. Blower doors can be used to answer the following questions:.
Infiltration has traditionally been assumed to contribute to the energy load of a building by an amount equal to the product of the infiltration flow rate and the enthalpy difference between inside and outside. Some studies have indicated that application of such a simple formula may produce an unreasonably high contribution because of heat recovery within the building envelope. The major objective of this study was to provide an improved prediction of the energy load due to infiltration by introducing a correction factor that multiplies the expression for the conventional load.
Increasing emphasis on energy-efficiency has many jurisdictions enacting stricter energy codes. Yet, these same green building codes typically do not adequately address ventilation when a building envelope is designed to both minimize infiltration/exfiltration and maximize thermal efficiency. Our company investigated an apartment complex in Southern California, U.S.A. that was designed 25% more thermally efficient than required by State Code. Within months of occupancy, the first complaints of biological growth at windows and closets occurred.
Air infiltration through revolving doors may have significant impact on the heating load of commercial and institutional spaces, and may create discomfort to people. This paper modifies a 40-year old model by Schutrum et al. (1961), composed of two components:
(1) estimation of air exchange between one segment of the revolving door and the indoor/outdoor,
(2) estimation of net air infiltration rate.
Convective air circulation occurring through wall layers is frequently observed in building envelopes. Significant thermal coupling can take place between the incoming cold/warm air and the wall structure, thereby modifying the thermal performances of the envelope. This paper presents an unsteady threedimensional numerical heat and air transfer model, which was developed to