Durable airtightness in single-family dwellings: field measurements and analysis

This study presents a comparison of air leakage measurements collected recently (November 2013 to March 2014) with two sets of prior data collected between 2001-2003 from 17 new homes located near Atlanta, GA, and 17 homes near Boise, ID that were weatherized in 2007-2008. The purpose of the comparison is to determine if there are changes to the airtightness of building envelopes over time. Durability of building envelope is important to new homes that are increasingly built with improved levels of airtightness.

Quality of Methods for Measuring Ventilation and Air Infiltration in Buildings

This publication includes the papers presented at the AIVC -TightVent-venticool Workshop: "Quality of Methods for Measuring Ventilation and Air Infiltration in Buildings", held in Brussels, 18-19 March, 2014.

Impact on IAQ of building material emitted pollutants through building leaks: State of the art and sample testing methodology

French authorities have launched an extensive thermal renovation program aiming at retrofitting 4M dwellings over 10 years, with priority given to the most energy consuming ones. Without specific focus on airtightness, retrofitting does not achieve very low airtightness levels, which means numerous leaks in the envelope. Added to the possibility of fungus development at the junction between ancient and new wall, the possibility of airflow conveying pollutants emitted in walls into indoor air is a major concern for public health.

Airtightness and ventilation of social housing in Ireland – A review of field measurements and occupant perspectives pre- and post- retrofit

Airtightness and controlled ventilation are important factors affecting energy use and indoor air quality. Airtightness tests were carried out on nine naturally ventilated social houses in Ireland. Subsequently, four of the houses were retested following energy efficient upgrading. The upgrading largely consisted of improving fabric insulation and where required the mandatory installation of passive wall vents. Interviews were conducted with the occupants to gain their perspectives of airtightness and ventilation in their homes.

Achieving relevant and durable airtightness levels: status, options and progress needed

The proceedings of the AIVC -TightVent International Workshop: "Achieving relevant and durable airtightness levels: status, options and progress needed" held in Brussels, Belgium, 28-29 March 2012

Securing the quality of ventilation systems in residential buildings - Existing approaches in various countries.

This publication collects papers presented at one of the activities organized in the context of the AIVC-project ‘improving the quality of residential ventilation systems’, primarily at the international workshop. 

Comparison of different airtightness and air exchange rate measurements in very small test building

The airtightness of the building envelope was studied in field measurements in recently constructed experimental small test buildings. Two types of research studies were carried out: the effect of special air tight sealing and the experimental determination of air exchange rate (h-1) under real operating conditions. In very small buildings with many joints between materials and construction the role of the air tight sealing is very important; the experiments show changes in measured air tightness.

Airtightness of very large volume buildings: measuring Method and first results

CETE de Lyon gives support to French administration for thermal regulation definition and enforcement. They must therefore work on measurements in order to set appropriate requirements and give advice to professionals about building methods.

Application of blower door measurements IN the evaluation of workmanship influence in airtightness

A large social housing retrofitting program was implemented in Porto, Portugal, a mild climate region. One of the features of that program was the upgrade of windows and ventilation systems. An increased airtightness was expected and mechanical extraction on kitchens and bathrooms was implemented. This work analyses the changes in building airtightness that resulted from that renovation.