Update of the spanish regulation regarding ventilation and infiltration: analysis, comparisons and repercussions

The Spanish Technical Building Code is one of the three royal decrees that were approved in Spain as a consequence of the transposition of the European Directive on the energy performance of buildings (2002/91/EU) [1]. One basic document of the Technical Building Code deals with the limitations in the energy demand of buildings. Nowadays, due to the recast of the European Directive on the energy performance of buildings (2010/31/EU) [2], a revision process of the current regulations has begun, starting with the Technical Building Code, with its first revision envisaged for 2012.

Lessons learnt from the regulatory quality management scheme in France

From January 1st 2013 on, the French energy performance regulation will demand that the airtightness level is justified and that airtightness of a building should be below 0,6m3/h/m² at 4Pa for single family housing and 1m3/h/m² for multi-family dwellings, resulting into an important growth in the airtightness market. It is the role of the State to accompany this market evolution and to supervise the quality of airtightness measurements used for the EP calculation. This is why it has been decided that there are two possibilities to justify the airtightness level of a building.

Postulate for airtightness limits in large buildings

DIN 4108-7 requires a limit of q50 ≤ 3.0 m³/m²h for the air permeability of large buildings. Even stricter limits with respect to q50 can be found at DGNB [German Sustainable Building Council] and in the Swiss MINERGIE Standard.
It is the objective of this presentation to develop awareness of this topic in the audience and to give recommendations as to which limits can be applied to new building projects.

Air leakage characteristics of dwellings in high-rise residential buildings in Korea

Reliable airtightness data is needed to calculate the estimate of air infiltration and the thermal loads for building energy efficiency and indoor comfort. While useful information on air leakage in low-rise dwellings does exist, there is little data available on dwellings in increasing high-rise residential buildings (particularly ones with central core plan). In this paper, we conducted airtightness measurement using fan pressurization method for about 350 dwellings in 4 high-rise residential buildings in Korea.

Proposal for updating french regulation concerning airtightness measuring equipments’ calibration

French standard for airtightness measurements is NF EN 13829. It is completed by French application guide GA P50-784, to set calibration rules more precisely, among other issues. This guide was published in 2010. To answer measurers’ remaining questions, a Frequently Asked Questions web site was created by CETE de Lyon.

Numerical evaluation of airtightness measurement protocols

In France, starting January 1st, 2013, the energy performance regulation will impose an airtightness treatment for every new residential building. This translates into several tens if not hundreds of thousands of envelope airtightness measurements a year that will have to be performed. They will have to be performed by a certified operator and according to the NF EN 13829 standard. This ISO standard is being revised under the Vienna agreement to become an EN ISO standard.

A survey of airtightness and ventilation rates in post 1994 NZ homes

The airtightness of 36 houses built since 1995 and across four cities in New Zealand (NZ) was measured. In a subset of 31 of these homes, the average ventilation rate was measured over several weeks in the winter using a perfluorocarbon tracer technique (PFT). These results can be added to earlier airtightness data to provide a platform for improving the air quality and energy efficiency of residential ventilation in NZ.

Assessment of the airtightness and air exchange in polish dwellings – measurement experiences and problems met

Indoor environment quality in buildings strongly depends on the proper ventilation. Still a large amount of single- and multifamily buildings are equipped with the natural ventilation system.
When the air exchange in the building is estimated, the main uncertainty concerns the air tightness of the given object. This parameter is used as the input data when the ventilation air flows in building are simulated, and therefore a reliable determination of the air tightness is essential.

Airtightness of office and educational buildings in Sweden – Measurements and analyses

The airtightness of office and educational buildings influences energy use and thermal comfort. A leaky building is likely to have a high use of energy and thermal discomfort. The knowledge of real airtightness levels of entire buildings and their impact on the energy use is very low, except for a study carried out in the USA. Therefore two different methods of airtightness testing were applied to six entire Swedish office and educational buildings built since 2000. The first method involves using the ventilation system of the building and the second one to use a number of blower doors.

Influence of improvement of air-tightness on energy retrofit of social housing, a case study in a mediterranean climate

In Spain, the residential sector is the third principal source of energy consumption; many of these dwellings are obsolete and do not have optimal conditions of comfort. For this reason, their energy retrofitting means an enormous step towards the energy efficiency. Under the general intervention strategies, the study and analysis of the air-tightness of the building envelope (as measured by the degree of infiltration) is a fundamental factor, because of its impact on energy efficiency, thermal comfort of occupants and indoor air quality.