Characterization of sealants and expanding foams

Constructions joints occur everywhere where several construction materials meet. That’s many meters that need to be taken care off, respecting the function that the materials or the joint need to fulfill. Typically a joint filled with sealing material has to account for water tightness, or is applied for esthetical reasons. Insulating materials can also be injected for thermal or acoustical insulation. A combination of joint materials often guarantees more advanced functions, fire resistance is a typical example.

Building airtightness in Germany -what are the driving forces

Building airtightness in Germany is on a good way. The latest survey amongst FLiB members shows the n50-values are much better than the benchmarks given in EnEV 2014 (German EPBD). For airtightness tests in 2014 the average n50-value of single-family houses is 1.1 ACH for new buildings and 1.6 ACH for refurbishments. In multi-family houses the average n50-value for new buildings is 0.9 ACH and 1.5 ACH for refurbishments.

Laboratory investigation on the durability of taped joints in exterior air barrier applications

In timber frame construction in Europe air barrier systems are typically realised at the interior side of the building envelope. Yet in some applications such as renovation projects it can be easier to provide the air barrier layer at the exterior. This way, the air barrier system – typically board materials in which the joints are sealed with tape – is exposed to outdoor weather conditions. The aim of the present article is to investigate the impact severe climatic conditions on the airtightness of typical taped joints.

Impact of air infiltration rates on moisture buffering effect of wooden surfaces

Interior wooden surfaces have the capacity to buffer the maxima and minima of relative humidity (RH) indoors. Especially in high performance buildings, where high airtightness levels as well as high indoor air quality (IAQ) are required, there is great potential for energy savings by reducing the mechanical ventilation demand. The last decade, the moisture buffer phenomena has been widely researched. Relevant findings showed that the moisture buffering effect is reduced when the ventilation rates increase.

Airtightness Data and Characteristics of 752 Residential Units of Reinforced Concrete Buildings in Korea

This paper presents airtightness data measured for about 752 units of high-rise reinforced concrete buildings (apartment buildings) that have been recently constructed within five years in Korea. Target buildings were mainly constructed by using reinforced concrete walls/floors, and dry/wet walls were installed between units. Airtightness data of residential units were analysed based on values of ACH50 and air permeability.

Multivariant measurements of airtightness of multi-family building

The paper presents airtightness measurements results of the multi-family building. The tests were carried out in several ways, the results obtained by different methods were compared and the likely reasons for the discrepancy of results were indicated. The object of measurements was a six storey building with 47 dwellings equipped with natural ventilation. Air inlet to the rooms through the window trickle vents controlled by relative humidity of air. Air is extracted through vertical extract ducts made of ceramic blocks.

rCloud - Capturing the moment, a new era in automated testing

Hand-written results are a thing of the past. See how your phone or tablet and common testing gear can perform an automated cloud based test with secure data storage. Retrotec’s new rCloud app allows technicians use their iPhone or 4G tablet to perform a fully automated blower door or duct test.
The rCloud app is more than an automated testing, it provides an entire data set from exactly where, when and the conditions of the test. It “captures the moment”

Estimating the average air change rate for the heating season

Ventilation of buildings and homes is a key issue both from comfort and energy aspects. However to determine the average ventilation air flow or the Air Change Rate (ACH) for a heating season by tests in case of natural ventilation, involve certain difficulties. Essential requirements when testing a physical phenomenon:

Airtightness and indoor air quality in subsidised housing in Spain

Over three million subsidised dwellings were built in Spain between 1940 and 1980. Most of these buildings are now obsolete and fail to comply with thermal comfort and ventilation standards. A building's existing energy performance, including its airtightness, should be determined prior to conducting low-energy refurbishment, for those factors, particularly the latter, impact thermal comfort, energy demand and indoor air quality (IAQ) fairly heavily.

Analysis of results from ATTMA lodgement –what are the realistic air permeability characteristics of UK housing

ATTMA, the Air Tightness Testing & Measurement Association has introduced mandatory lodgement for all members, representing over 140 companies and over 350 test engineers across the UK. This presentation will give an oversight as to how we have made lodgement mandatory, the software we are using and finally some statistical analyses showing where the UK is at the moment with average Air Permeability (AP50) results.

Pages