The 15th AIVC Conference - The Role of Ventilation, was held in Buxton, UK, 27-30 September 1994.

Contains 75 papers.

Volume content

Enter a comma separated list of user names.
The aim of this study was to unravel the occupational exposure to radon among underground workers. The possibility for radon mitigation by improving ventilation or by sealing was also investigated.
Korhonen P, Kokotti H, Kalliokoski P
The fan and the ductnetwork is designed for 100% ventilation rate. Because the fan energy is the main important energy consumption in systems all over the year it is worthwhile to control the systems correctly.
Steimle F
The adequate ventilation of houses is essential for both the occupants and the building fabric. As air-tightness standards increase, background infiltration levels decrease and extra ventilation has to be designed into the building.
Palmer J, Parkins L, Shaw P, Watkins R
The reason for the present project is the need for more reliable information about the actual ventilation conditions in naturally ventilated, detached houses.
Bergsoe N C
The "Passivhaus Darmstadt-Kranichstein" is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m² of living area, thereof about 12 kWh are needed for room heating /Feist 1994/.
Feist W, Werner J
A measurement system is described to record the movement in a room of neutral density balloons or bubbles, and thus the movement of air in that room.
Alexander D K, Jones P J, Jenkins H, Harries N
The paper presents some selected results of evaluation of improvement effectiveness of thermal insulation and tightness of multifamily dwelling houses located in the region of Silesia.
Nantka M B
This paper reports on the findings from two extensive laboratory studies of ventilation of bathrooms of different sizes and layout of ventilation. The ventilation flow rates were varied.
Sandberg M, Blomqvist C
Ventilation of the void below suspended timber floors is necessary to prevent dampness, which leads to wet and dry rot.
Harris D J, Dudek S J M
In the frame of the European PASCOOL project, several experiments regarding single sided ventilation were carried out at BBRI in the outdoor PASSYS test cel. The test room of 30 m³ has a vertical window of about 1 m².
Ducarme D, Vandaele L, Wouters P
This paper shows preliminary results of 18 out of 30 inspected ventilation systems in low rise, low energy residential buildings. We propose a method for the assessment of energy efficiency of ventilation systems.
Werner J, Rochard U, Zeller J
This paper briefly reviews the weather data available for natural ventilation and briefly reviews hourly data for simulation. It starts by reviewing the need for basic data for initial manual calculations.
Arif M J M, Levermore G L
A kitchen is one of the major moisture producing areas in a dwelling. In order to prevent condensation and mould growth the relative humidity should not be too high.
Shepherd T, Parkins L, Cripps A
The paper summarises an approach to determining the equations governing the air flow through simple cracks subject to fluctuating pressures.
Sharples S, Palmer R G
Terminals are used on all types of ventilation system exhausts, often to prevent rain water and animal entry, but also to prevent wind induced flow-reversal and enhance wind induced updraught.
Welsh P
New Zealand homes have traditionally been ventilated through open windows and by background infiltration.
Bassett M R