Sorensen DN
Year:
2002
Bibliographic info:
Proceedings of Room Vent 2002 (8th International Conference on Air Distribution in Rooms) - 8-11 september 2002 - Moltke's palace, Copenhagen - Denmark - pp 317-320, 1 figs, 3 Tab., 6 ref.

A seated, unclothed and bald manikin is used for the experiment. A numerical method calculates the view factors between individual segments of a thermal manikin , and between the outer surfaces and the body segments. The segment to segment radiation is the subject of the research : radiation between segments may be significant and the local differences in radiative heat loss may cause discomfort and cannot be ignored.