Chiang C M, Chou P C, Lai C M, Wang W A, Chao N T
Year:
1998
Bibliographic info:
Sweden, Stockholm, KTH Building Services Engineering, 1998, proceedings of Roomvent 98: 6th International Conference on Air Distribution in Rooms, held June 14-17 1998 in Stockholm, Sweden, edited by Elisabeth Mundt and Tor-Goran Malmstrom, Volume 2

This study utilizes the two-chamber model to simulate naturally ventilated airflow through a window opening in a common- type bedroom in Taiwan. Standard kepsilon turbulence model is implemented to account for such a natural convection flow pattern. The driving force in this space is mainly the heat flux generated by occupant's skin. The result shows that under normal operation indoor, carbon dioxide ( indicator air contaminant for IAQ ) is less than 1000 ppm, ASHRAE Standard recommended.