Modera M P, Sherman M H
Year:
1985
Bibliographic info:
Preprint. ASHRAE Transactions 1985, Vol 91 Pt 2. HI-85-03 No 3. 12p. 4 figs, 2 tabs, 20 refs.

This report presents a new technique for measuring the leakage area of residential buildings. This technique, called AC pressurization, is designed to overcome most of the shortcomings of fan pressurization, the conventional technique for measuring leakage area.