The effect of insulation, mode of operation and air leakage on the energy demand of dwellings in the U.K.

Describes results of computer study of behaviour of 2 better insulated houses, one of rationalised traditional and one of timber frame construction. Compares their performance with a contemporary house. Provides most important results regarding mode of operation and effects of air leakage. Concludes that better insulation is effective energy conservation measure but heavyweight characteristic of insulated structures result in intermittent heating being a less attractive means of reducing heat demand. Air leakage, if not controlled, becomes animportant component of the total heat loss.

The development of tracer gas methods for measuring air changes. Utveckling av spargasmetoden for matning av luftvaxling.

Notes principle of air change rate measurement using natural growth exponential equation to measure concentration of tracer gas. Experience shows that period required for satisfactory measurement is often periodicity of air change rate. Diagram relates linear and logarithmic scales used in air change equation. Describes use of pre-programmed gas analysis equipment allowing extrapolation to forecast results. Uses microprocessor for evaluation. Also discusses importance of instrument calibration.

Ventilation in single family dwellings - a system analysis. Ventilation i smahus - ett systemanalys.

Describes sealing houses against air infiltration to allow controlled ventilation. Notes inherent risks in poor ventilation such as high radon content and its associated decay products, poor air quality, moisture, condensation, mould and allergy-producing dust particles. Treats requirements in swedish building code and stipulated minimum air change rate. Comprehensive series of graphs illustrates air change rate as function of wind speed and different grades of building air tightness.

Window airtightness and its influence on energy saving and minimum required ventilation.

Presents method for establishing conditions and an acceptance criterion for window air-tightness testing in relation to average energy (heating) saving per winter. Uses wind velocity data from israeli meteorological station of Ashdod to demonstrate difference between various methods of evaluating design wind velocity. Uses 41 different typical dwellings to determine unique criterion for acceptable air leakage under test conditions which ensures average of 1 air change per hour in most Israeli dwellings.

Control of air leakage is important

Points worthy of consideration regarding air leakage, i.e. the causes, identification, problems and remedies are briefly discussed generally without technical details and some illustrations are given of problems. Air leakage is common in most buildings, but with increasing standards of performance and the trend to taller buildings, it is becoming less tolerable. Reference is made to other CBD reports in which details are specified. The positive control of air leakage can only be achieved by careful attention in design and adequate inspection during construction.

A review of experimental techniques for the investigation of natural ventilation in buildings.

After discussing briefly the principles of natural ventilation, goes on to describe tracer gas techniques, air movement measurements, and various model techniques including analogues. Advantages and disadvantages of each method are indicated, andtheir suitability for particular applications.

The influence of wind and sun for weather dependent control of central heating installations.

Discusses control from outdoors and gives a formula for the heat required to maintain indoor design temperatures. Outlines the twofold effect of wind, i.e. the increase in the heat transmission coefficient for outside walls, and increased ventilation and air infiltration caused by pressure differences. Explains the solar effect by formulating the heat load on the outer walls and through the windows. An example illustrates the calculation procedure. Tabulates the increase in heat consumption due to wind; this varies with wind speed, building location and height.

How to determine building infiltration rates at low Reynolds numbers.

Assuming higher than probable cd values for crack length openings on calculation of infiltration rates results in excessive allowances for heating and cooling capacity. Using a given cd graph, proposes equation to determine infiltration rates and reduce internal pressurization requirements to offset wind impingement.

Moisture accumulation in walls due to air leakage.

A number of cases of water and frost damage in masonry and non loadbearing walls have been examined. This damage could not have resulted from vapour diffusion or rain penetration and is primarily caused by condensation due to exfiltration of air. Air exfiltrates through the many cracks and joints and in this connection the result of chimney action and wind is explained in some detail, including the pattern and magnitude of building pressure differences that induce ex-filtration together with a discussion regarding the moisture that is transferred.

Ventilation measurements in houses and the influence of wall ventilators.

Using nitrous oxide as a tracer, the author made 390 measurements of ventilation rates in seven closed rooms of six houses, in Melbourne, Australia. Half of the observations were taken when the wall ventilators were sealed, in order to explore their influence on room ventilation. Results for each room, grouped in ranges of wind direction and according to whether ventilators were open or closed, are shown as regression curveson plots of ventilation rate against wind speed. The ventilators are shown to have only a slight effect on ventilation.