Experimental characterisation of ventilation systems in buildings.

Reports experiments using sulphur hexafluoride as a tracer gas to obtain quantitative data on actual residence time distributions in rooms and hallways and contamination caused by reentry of laboratory fume hood exhausts into a building. Defines a factor k which gives a measure of the mixing of fresh withstale air in part of a room. Measured values of k varied from 0.3 to 0.7 insmall rooms without fans. Discusses two experiments to find the amount of exhaust fumes reentering the ventilation system of a building.

Wall thermography

Describes use of thermography by Fishburn Thermography group ltd. Outlines use of camera and isotherm function. Suggests use of thermography for the detection in walls of heat losses, thermal bridging, wet or inadequate insulation, air infiltration and other defects.

A spire array for generating thick turbulent shear layers for natural wind simulation in wind tunnels

Investigates use of an array of spires, located at the entrance to the working section of a conventional wind tunnel, as a means of generating thick shear layers with properties similar to those of the neutrally-stable atmospheric wind. Compares data obtained in the shear layers created by sucharrays of spires with some available atmospheric data. Modifications to thespire design and a range of spire sizes have been tested and the resulting shear layer properties compared.

Measured energy consumption of a group of low-energy houses.

Reports survey of the energy consumption of 50 low-energy passive solar houses in the Saskatoon area. Gives graphs of energy consumption versus degree days for standard and low-energy houses and space heating consumption per unit floor area. Gives table of measurements.

Design principles

Outlines forces causing air leakage through openings in a building. Discusses likely leakage paths and states importance of identifying these and improving the air tightness of walls, windows, floors and roofs.

Application of design principles in practice

Discusses in general terms the importance of attending to detail in construction. Gives examples of faulty design and construction.

Ventilation rate in modern flats. Luftskiftet i nyere boliger.

Reports measurements of air change rates carried out in the living rooms of 39 flats built during the last 20 years using Freon 12 as a tracer gas. Ventilation rates ranged from 0.3 to 2.9 changes per, hour, the average being 1.3 changes per hour. Air temperature, humidity and wind speed were recorded and the ventilation rates corrected for wind speed and temperature. Notes large ranges in ventilation rates for similar flats.

Indoor air pollution in Rotterdam homes.

Reports study of 800 paired samples of indoor and outdoor smoke and SO2 concentrations of 60 Rotterdam homes. Finds that smoking increased the amount of smoke found in living rooms and the data suggest that newer houses tend to have less SO2 in the living rooms than older houses. On average living rooms contained approximately 80% of the smoke and 20% of the SO2 measured simultaneously outdoors during 24 hour periods. Estimates probability of having more SO2 in the living room than outdoors is less than 2%.

Model testing of the wind pressure on a house, with and without a wind break. Modellversuch uber den Winddruck auf ein Haus ohne and mit Windschutz.

The wind pressures on a building can be decreased by a shelter hedge. Gives results of wind tunnel tests which show how this shelter effect depends on the distance between hedge and house, and on the wind direction.

Wind baffles. a proposed method for limiting the influence of wind on the ventilation pattern in livestock houses. Winddruckkap een voorziening om de invloed van de wind op het ventilatiepatroon in stallen te beperken.

Animal houses such as piggeries and cattle sheds are commonly ventilated using extraction fans in the ridge of the building. Fresh air is introduced through wide openings. These openings are screened by a baffle. Describes improved design of baffle which caters for a constant pressure difference between the inside and outside of the house.