An Experimental Study on Chair Air Supplying

Displacement ventilation is acknowledged to be an efficient system for the removal of contaminants and excess heat from occupied zones of rooms, this system is aiming at supplying clean undiluted supply-air directly to the zone of occupation. Air flow rate, temperature and the design of the supply device strongly influence the parameters that determine thermal comfort. In the paper, one kind of displacement ventilation systems - ohair air supplying system is investigated.

A Mathematical Model of Downdraft Exhaust Hoods

The purpose of the work described in this paper is to develop a mathematical model of downdraft exhaust hoods in order that ways of improving these hoods efficiency can be examined. In this initial study the model developed is twodimensional. The flow has been assumed to be ideal and the complex potential considered. By use of conformal mappings the airflow in the vicinity of a bench, which is extracting air and also has air being blown down from above, is modelled. Various ratios of extraction to downdraft are considered in order to investigate the most efficient method of operation.

Effects of a Ventilation Duct on the Performance of a Fume Cupboard

When a fume cupboard is placed in a room with a ventilation duct, the air movement inside and around the fume cupboard is fully three-dimensional turbulent flow. However, in order to understand the fluid flow away from the fume cupboard a much simpler model can be used. This leads to a steady 20 model, with the computational domain including only the sash of the fume cupboard, the room and the entrance into the ventilation duct. In this paper we have used both the k-E turbulence model and the wall function technique to calculate the steady 20 turbulent fluid flow.

Vortex Air Distribution System for Boiler House

This article describes a new and more efficient Vortex Air Distribution system for a soda recovery boiler house. Essentially th.e technology utilises directional air supply of up to 150 m3/s to compensate for beat gains of up to 2000 kW. Issues addressed include all stages of the design process from the Computational Fluid Dynamic (CFO) experiment and scale mock-up tests in the laboratory conditions to the field measurements after the system had been installed. The supply air is distributed into the building through specially designed air terminals.

Test Room and Measurement System for Active Displacement Air Distribution

A test room and measurement system were developed for the full-scale measurements of the active displacement air distribution. The room represents a 3-meter wide module of a larger hall. The requirements for the room included minimisation of the errors caused by air leaks, thermal conductance and flow obstacles. The measurement of the flow pattern is carried out with ultrasonic and thermal anemometers. Automated traversing system was built to move the sensors in the vertical symmetry plane of the room.

Open Source Cooling

                

Air Flow Characteristic in Scale Models of Room Ventilation

Improvement in methods of air flow pattern scale modelling in large enclosure requires above all, précising the conditions necessary in the model in order to maintain Reynolds number independence of the mean flow, as well as defining ways in which the flow turbulent structure could be simulated. The paper presents the results of experimental analyses of air velocity fields in scale models in the range of Reynolds number 1850 to 98000. The field maps of air velocity mean value were tested.

The Evaluation of Natural Ventilation in Underground Office Space

One of the major factors in human comfort is the air quality, which occupies a specific environment and is usually renewed through natural ventilation. However, isolated underground spaces do not benefit from this factor and are often subject to high relative humidity, poor air quality, pollutant emissions and penetration of moisture from the surrounding soil and ground base. Due to such negative characteristics, underground spaces are generally recognized as undesirable living environments by most of Koreans.