Improvement of indoor climate and ventilation system in a renovated multistoried residential building.

The goal of this project was to improve the quality of indoor air in a multistoried residentialbuilding of 81 flats built in 1960. The building is located in a heavily built urban area ofHelsinki. The building had a mechanical exhaust ventilation system without outdoor air inlets.A questionnaire was sent to occupants and a condition survey was made prior to renovation. Themain indoor climate problem was draught with a prevalence of 60 %. Other almost as commonproblems were traffic noise also during nights and dust coming from the street.

Heat recovery in natural ventilation design of office buildings.

Heat recovery in ventilation systems for office buildings in cold climates is necessary for tworeasons:1. To obtain acceptable indoor thermal comfort by preheating of fresh air,2. To reduce ventilation energy lossThis paper describes a pilot system built in the laboratory of the Norwegian Building ResearchInstitute, NBI, based upon the concept of an advanced fan assisted natural ventilation systemwith heat recovery. The concept was developed by NBI.

Experimental impact valuation of fouling on extract air terminal devices performances: an accelerated artificial fouling approach.

A humidity controlled air flow terminal device works as a humidity sensor : its openingsurface varies according to relative humidity inside a room in order to match air flow rate topollution. These components are fouling up when used during several months.In a laboratory, an air flow with a high rate of particules is fouling up five identical air devicesin a few hours. Considering a constant relative humidity, the impacts on two devices aresimilar : it seems that artificial fouling tests can be reproduced.

Displacement ventilation in a classroom - influence of contaminant positioning and physical activity.

This study describes how the air quality in a displacement ventilated classroom can beinfluenced by the position of a contaminating person, and by the activity of a person who walksaround in the room. Tracer gas measurements have been performed in a full scale mock-up of aclassroom, with person simulators at the student's desks.The spreading of contaminants from a person seems to be strongly dependent on the positionof the person. The closer the contaminating person sits to the outlet terminal(s), the less ofhishers contaminants are spread in the room.

Comparison of IAQ performances of French ventilation systems in residential buildings.

Until now, there is no widely accepted way to express any index for this purpose and takinginto account the large variety of possible pollutants. Things can be simplified is the aim is moreto compare different systems and strategies than to give an absolute value of quality.For the study of a pollutant source, the main important point for comparison is the pattern ofits production, whatever this pollutant is.

Building performance evaluation for indoor air quality using occupant contaminant inhalation and attribution to contaminant sources.

The emissions of building materials like volatile organic compounds and indoor airbornecontaminants such as environmental tobacco smoke expose occupants to hazardowsubstances. Although impacts of indoor air quality problems on human health, comfort, andproductivity are quite large, no adequate evaluation methodology exists to assess contaminantsource control techniques and building equipment systems.

Assessing natural urban ventilation through an integrated model.

The paper presents further then an integrated model the supporting methodology that allowsto assess natural urban ventilation conditions both outside and inside constructions.Though some particular aspects arid procedures can be complex and time consuming thegeneral structure is quite simple:1. to establish wind regimes as a boundary condition - information can come from windmeasurements at undisturbed areas Like airports;2. to integrate these regimes within the site - using numerical models to transfer information tothe site;3.

Analysis of duct systems for variable ventilation flow rates.

Ventilation systems using variable airflow are useful in urban areas. Due to outdoor pollutionand the indoor load from pollution or thermal sources, it is important to vary the airflow. Thismust be done without disturbing the control of the total distribution. To analyse suchproblems, there is need for a design aid. This paper presents a first version of a modularsimulation program working in the IDA environment. The program is based on a set ofindividual component-models in the NMF (Neutral Model Format) language.

Airtightness of timber frame buildings without a plastic film vapour barrier.

Good airtightness of a building can be achieved by the incorporation of an inner sealing layerfor the exterior walls and roofs in the form of a plastic film, which also serves as a vapourbarrier. However, if it is not wished to use plastic film as an inner sealing layer, thenairtightness must be effected through the use of other materials or in some other way. Thisproject has been concerned with investigation of a number of alternatives.

Active envelopes - essential in urban areas?

Today, the development of new technologies to improve building envelope performances ishighly encouraged and provides a clear challenge for designers and researchers. In thiscontext several typologies of active envelopes have become very popular. The paper startswith an overview of the history and the performances of active envelopes in the context ofurban design.