MJM ACOUSTICAL CONSULTANTS INC. has been retained by the CANADA MORTGAGE & HOUSING CORPORATION to conduct a research project on the noise isolation provided by access doors in multi-dwe.lling buildings. A total of nine Sound Transmission Loss (TL) tests were conducted on four 1 3/4" doors (one wood door and three metal doors) and one 2 1/4" wood door. This research project has also been used as a preliminary attempt to validate a simple method to m. easure the Sound .T ransmission Loss and. Sound Transmission Class of a door when it is installed on site.
This Update presents guidelines for controlling the transmission of impact sound through concrete-slab and wood-joist floor systems in multi-family dwellings. It is based primarily on industry-supported research conducted by IRC.
Fuel-burning appliances require air for combustion. When the appliances are located in enclosed spaces, provision must be made for supplying the required amounts of air. Depending on the specifics of the appliances and the enclosure, additional air may be required for draft hood dilution and space conditioning. An enclosed space can be a mechanical room in a building, a furnace room in a residence or the entire floor of a building if a separate enclosure is not used to isolate the combustion appliance(s).
The paper presents a ventilation comfort chart that has been developed under Thailand climate and using Thai volunteers. 183 male and 105 female college-age subjects were exposed to different thermal conditions in order to investigate the effect of air velocity on thermal comfort in ventilated "non-conditioned" spaces. To this end commercial electric fans were used to control the air velocity near the subjects. The air velocity varied between 0.2 and 3 m/s. Room conditions varied between 26°C and 36°C (D.B.T.) and 50-80% relative humidity.
This publication summarizes current information on heating (both space and hot water heating), cooling and ventilation systems and equipment used in low-rise, residential buildings with regards to their effect on indoor air quality. An additional discussion of water purification systems is also presented.
A park influences its surroundings. Temperature inside and around the park varies in a special way. Air quality also varies. And the park creates its own wind system.
A programme of work involving the measurement of ventilation rates, air velocities and temperatures has been completed within a naturally ventilated auditorium in the Queens Building, De Montfort University. Measurements have been recorded for 'winter', 'mid-season' and 'summer' conditions, and average occupancy levels.