Improvement of airtightness in four schools.

Air leakage tests (using the fan pressurisation method) were conducted on four schools, before and after they were retrofitted, in order to determine the effectiveness of various measures for reducing leakage. Caulking wall joints will generally reduce air leakage and is worthwhile if the joints are accessible. Replacing leaky windows will also improve airtightness but may not be cost effective. Routine inspection of outside dampers of the air handling system can help ensure continued airtightness of schools.

The effect of tracer gas on the accuracy of air change measurements in buildings.

Compares the air change rates measured using the decay method with several different tracer gases. Tracer gas measurements were conducted in a tightly sealed room where constant air leakage rates were maintained using an exhaust fan. Tracer gases investigated were CH4, CO, CO2, N2O and SF6. Agreement between tracer gas measurements and measured flow rates of the exhaust fan was very good for CH4, CO and N2O. The agreement was also satisfactory for CO2 and SF6, but the scatter in tracer gas data was much greater then it was for the other three gases.

Mark XI energy research project. Summary of results 1978-1981.

Reports on a study carried out by HUDAC and DBR on four identical detached houses built in Ontario in 1977. House 1 was built according to the insulation requirements of the 1975 Ontario Building Code, the others were constructed with increased levels of insulation and air tightness. Some of the aims are:

Energy reduction opportunities in small commercial buildings.

Gives some conclusions from a detailed computer analysis of the energy consumption of 600 branch bank buildings of The Bank of Novia Scotia, spread across Canada. Divides energy management into 3 categories:

Caswell Hill infiltration work-study project. Final report.

Reports on a project carried out in the Caswell Hill and Riversdale areas of Saskatoon to investigate the effectiveness of sealing with caulking and weatherstripping to reduce air leakage. This involved sealing 10 homes, and also insulating the attics and basements of five of these houses after thesealing work. A control group of 10 homes which had been insulated without particular attention being given to sealing procedures were also monitored. The homes were pressure tested by the National Research Council before and after sealing to measure the reduction in air leakage.

Energy program validation: conclusions of IEA Annex 1.

States that the calculation of building energy flow is very complex, and so validation is a vital element in the development of any model. Describes an IEA R and D project to compare 23 computer programs (from 8 different countries) both in terms of consistency between programs, and in thei relative accuracy in modelling the behaviour of a real building (the Avonbank office block in Bristol). Summarizes the major conclusions developing out of the project and discusses the most important aspects which need to be considered in the development of a reliable computer program.

Computer simulation of wind flow around buildings.

Describes the relationship between wind flow round a building and heat loss from it. The relative merits of numerical and wind tunnel models are discussed and various numerical techniques, including the vortex method and the control volume method, are examined.

Validation of buildings and systems energy prediction using real measurements.

Looks at the requirements for computer model validation, especially in regard to predicting energy usage in buildings. Discusses the IEA project for comparing and validating several computer programs in this context. Describes the Glasgow commercial building monitoring project, which includes detailed measurement of temperature and air flow rates to provide data for model validation. States what type of data is needed for validation.

Radon-222 in energy efficient buildings.

Describes sources of radon in buildings. Summarizes data on observed indoor radon concentrations in houses in New York, Salzburg Austria, and Florida. LBL studies in energy efficient buildings in Maryland, Minnesota, and New Mexico show that tight houses have higher radon concentrations then conventional houses. The data reported is based on "grab samples" taken on mild days (low wind and small indoor and outdoor temperature differences) with all doors and windows closed, resulting in a "worst case" estimate.

Impact of energy conservation in buildings on health.

Briefly reviews sources and types of air contaminants common in tight houses. Covers four indoor pollutants - carbon-monoxide and nitrogen dioxide from gas stoves, particleboard plywood and urea-formaldehyde from insulation, and radon from various building materials.Suggests ways of lowering pollutant levels without compromising energy conservation considerations.