Stack driven ventilative cooling for schools in mild climates: analysis of two case studies

This paper presents two case studies of stack driven ventilative cooling systems implemented in kindergarten schools located in the mild Subtropical-Mediterranean climate of Lisbon, Portugal. Both systems rely on stack driven natural ventilation supplemented by a larger, single-sided ventilation opening to be used in the warmer months. In both systems air enters the rooms at a low level, directly in front of the heating passive convector systems, and is exhausted in the back of the room, through a chimney.

Night time cooling by ventilation or night sky radiation combined with in-room radiant cooling panels including Phase Change Materials

Night sky radiative cooling technology using PhotoVoltaic/Thermal panels (PVT) and night time ventilation have been studied both by means of simulations and experiments to evaluate their potential and to validate the created simulation model used to describe it. An experimental setup has been constructed at the Technical University of Denmark, where the outside PVT panels are connected through a storage tank to in-room radiant ceiling panels. The radiant ceiling panels include phase change material (PCM) and embedded pipes for circulating water.

Evaluation tool of climate potential for ventilative cooling

The new initiatives and regulations towards nearly zero energy buildings forces designers to exploit the cooling potential of the climate to reduce the overheating occurrence and to improve thermal comfort indoors. Climate analysis is particularly useful at early design stages to support decision making towards cost-effective passive cooling solution e.g. ventilative cooling.

BIM, information on sustainable building and performances

There is an expanding literature on the value of sustainability features in buildings (European Commission, 2013; World GBC, 2013; World GBC, 2014). While several publications focus on the price differentiation between buildings with sustainability credentials and buildings with no sustainability credentials (Eichholtz et al., 2010; etc.), others examine the costs and benefits of sustainability features individually referring to both monetary and intangible values (Heerwagen, 2000).

Is ventilation necessary and sufficient for acceptable indoor air quality?

The role of ventilation in achieving acceptable indoor air quality is examined in the light of emerging challenges, alternative mitigation strategies and performance indices within the spatial and time matrix of the indoor environment. By considering the source of contaminants, their nature, transportation mechanism and participation in source-sink relationships, several studies have shown that it may not be feasible nor adequate to rely on ventilation alone to attain the desired level of exposure, especially with respect to airborne aerosolised droplets with infectious potential.

Ventilation projects within the international energy agency: objectives, approaches and expected results

This key note presents the objectives, approaches and expected results of the on-going annexes relevant for ventilation and air infiltration in buildings and illustrate the importance of and expectations to an increased cross-annex coordination and cooperation.

Energy efficient ventilation for NZEB in Mediterranean countries

In the definition of the nZEB, the use of only one requirement is misleading. Different requirements are combined to a coherent assessment of an nZEB and to fit the definition given by the EPBD (2010/31 /EU) in article 2. In this presentation, we focus on the first requirement reflecting the performance of the building envelope characterised by the energy needs for heating and cooling.

Indoor air quality regulations. The Spanish case

The current regulation in Spain regarding Indoor Air Quality (IAQ) provisions is Building Code (Código Técnico de la Edificación) for dwellings and Regulations on Building Heating Installations (Reglamento de las Instalaciones Térmicas en los Edificios. RITE) for other kind of buildings.

Air change rate measurements using indoor/outdoor ratio of PM2.5

According to past researches, most people spend 80%-90% of their time indoors. The ventilation is very important to people’s health and the comfortable surroundings around us. From the viewpoint of energy saving, mechanical ventilation will consume a large amount of additional energy. So variety of ways measuring natural ventilation is worth considering. In fact, in real life, many people tend to have their windows shut rather than open, and the reasons are complex.

How to construct a domestic pitched roof with high thermal quality?

The paper at hand collects research findings on the impact of air flow on the thermal performance of pitched roof assemblies. Air flows in these components are typically a mixture of: 1) in/exfiltration, 2) natural convection and 3) wind-washing. In the current building practice the necessity of an air barrier to guarantee the thermal and hygric performance of roofs is well established. Yet the need for a continuous wind barrier to avoid wind-washing of the insulation layer is still often underestimated in practice.