This page lists the Proceedings (titles and abstracts) of the 11th International BUILDAIR Symposium, held on 24- 25 May 2019 in Hannover, Germany.

Contains 25 titles and abstracts. 

Volume content

Enter a comma separated list of user names.
The requirements concerning airtightness of the building envelope were introduced into the national standard ČSN 73 0540-2 in 2002. Until now the proof of compliance has not been mandatory. The compliance should be checked by means of testing according to the ČSN EN ISO 9972 standard (introduced in 2016 and translated into the...
Jiří Novák
Even though air leakage assessment is key towards a better energy performance of buildings, Spain has still not established limitations regarding airtightness. National building regulations in Spain are gathered in the National Building Code (CTE), which was first released in 2006 and updated several times so far. Airtightness should be...
Irene Poza-Casado
The situation in Switzerland is as follows: Neither the Swiss Energy Act nor cantonal energy acts/energy regulations stipulate a legal measurement of airtightness. The current standards of the Swiss Engineers and Architects Association (Schweizerischer Ingenieur- und Architektenverein, SIA) are the latest standards for architecture...
Gregor Notter
What is recommended in the way of building preparation (methods 1, 2, 3)? For methods 1 and 2, the Austrian national annex to ISO 9972 page 6, Item 6.3, Table 1, applies. For method 3, there are no references in the national annex. In this case, ISO 9972 applies. If method 3 is selected, is a checklist drawn up? Of interest is the issue...
Michael Pils
The current French EP regulation called “RT 2012” imposes a maximum airtightness level2 of residential buildings envelope: 0.6 m3.h-1.m-2 for single-family houses and 1 m3.h-1.m-2 for multi- family buildings. The respect of these requirements must be justified either with an airtightness test of each building or by the application...
11th International BUILDAIR Symposium, 24- 25 May 2019, Hannover, Germany
For approx. a year ago, the following was submitted to the Certification Committee, and no response is still seen. Especially the problem of the pressure at which Pa the measurement should start is seen as a criticism, and yet it has not been possible to find a reasonable explanation for the change...
Lars Due

Pages