Synnemar K.E.
Year:
1982
Bibliographic info:
Bygg. October 1982 p.68 2 figs. #DATE 01:10:1982 in Swedish

Notes job losses in prefabricated timber housing industry in Sweden and Hjaltevad's endeavours to produce a large series popular house with low-energy characteristics. House is on one and a half floors and has an occupied area of 150 sq.m. Heating economy is strongest sales argument with estimated annual consumption of 8000 Kwh. Low energy consumption results from electric boiler and heat pump. The heat pump assumes a mechanical exhaust air system and heat extracted is added to hot water system. Notes strict control of tightness before external cladding is nailed in position. Each house is tightness checked during production and an average value of 0.65 changes/hr at 50 Pa is recorded.