Four year on site measurement of heat flow in slab on ground floors with wet soils.

Trethowen H A, Delsante A E, 1998
floor | heat transfer | insulation
Bibliographic info: USA, Atlanta, American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), 1998, proceedings of "Thermal performance of the exterior envelopes of buildings VII" a conference held Sheraton Sand Key Hotel, Clearwater Beach, Florida
Languages: English

This paper outlines the methods and results of a four-year project that measured heat flows through two uninsulated slab-on ground floors on nominally wet soils. One floor was on peat soil, the other on clay, and water table depths were 0.5 m to 1.0 m through most of the year. Heat fluxes were measured over the whole floor using heat flux transducers (HFT) at the concrete floor surface, and temperatures were measured by thermocouple, continuously for four years. The soil conductivities and soil temperatures were measured daily at 11 positions near one edge of the floors.