Zhu Q., Kato S., Murakami S., Ito K.
Year:
2007
Bibliographic info:
Indoor Air, Vol. 17, n° 3, pp 178-188

For that paper, the flow field and the emission field of VOCs from the surface of building materials in a FLEC (Field and Laboratory Emission Cell) cavity are investigated by 3D CFD analysis. Emission phenomena controlled by internal diffusion, or by external diffusion, or by mixed diffusion are studied. The results and conclusions are presented.