Verification of energy saving in residential housing

Today energy saving rates due to retrofits in residential housing are either measured by experiment on site or predicted by system simulation. In the latter case mathematical models of the components are developed, verified by laboratory tests and combined to represent the thermal characteristics of the investigated system. Then energy demand is calculated before and after adopting the investigated retrofit. There still remains the question, are energy savings precalculated by system simulation: obtained in fact, in other words do they agree with results of field experiments.

Three-dimensional modelling of SLAB- on grade heat transfer

Experimental studies during the 1940S concluded that heat loss from slab-on-grade floors is proportional to floor perimeter length. More recent numerical investigations, however, indicate that area and shape are also important parameters. Furthermore, results of three-dimensional modelling differ significantly from those of supposedly equivalent two dimensional analysis. Earth-coupled heat transfer processes are increasingly important contributors to building energy consumption, but continue to be poorly understood by most designers.

Thermal energy storage system sizing

This paper describes results from a larger project [1] which investigated the sizing of Thermal EnergyStorage (TES) systems used as part of the cooling system in buildings. The study was based on DOE-2simulations; daily integrated cooling coil energy requirements for office and retail buildings in theChicago, Fort Worth, and Miami climates were examined in relation to climate and operational parameters.

The use of the combine program with DOE-2.1C

COMBINE is a file utility program developed by Jeff Hirsch of Lawrence Berkeley Laboratories for use with the DOE2.1C building energy simulation program. COMBINE merges the data arrays that are passed from the SYSTEMS simulation subprogram to the PLANTS simulation subprogram in DOE2.1C. To date, it has not received extensive publicity but it is a program that expands the applications and power of DOE2.1C and it deserves recognition as one of the most practical building energy simulation innovations of the past several years.

The simulation of building lighting systems

This paper describes a recently developed, multi-chromatic lighting simulation model, known by the acronym DIM (Digital Illumination Model). DIM accepts a description of a zones geometry, surface finishes, contents and natural and artificial light sources. A multi-chromatic raytracking scheme is then employed to obtain the surface spectral luminance distribution corresponding to each light source. Outputs from the model include data on planar illuminance and coloured perspective images.

The interaction of building lighting and HVAC systems

Over the past 5 years, Dubin-Bloome Associates (DBA) and Ross & Baruzzini, Inc. (R&B) have jointly been working on a project to determine the relationship of the air conditioning load caused by building lighting with time. Our effort has been funded by the Electric Power Research Institute. An initial literature search determined that the basis of existing calculation methods was data generated by Mitalas in the 1950's for a very limited set of experiments.

The cost of increased ventilation air

The present American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) standard 62-1981 "Ventilation for Acceptable Indoor Air Quality" is being revised. The recommended ventilation rate will be increased four-fold from 2.5 I/s/person to 10.0 I/s/person. The immediate response to this proposal is that the energy consumption and costs will parallel this increase and rise dramatically. It is the intent of this paper to provide a better understanding of the actual effect of the changes to the ASHRAE standard.

The COMIS infiltration model

The task is for COMIS to develop a reliable and well running multizone infiltration model on a modular base. This model does not only take crack flow into account, but also covers flow through large openings, single sided ventilation, cross ventilation and HVAC-systems. The model contains a large number of modules, which are peripheral to a steering program. COMIS can be used as a basis for future expansions in order to increase the capabilities of simulating buildings or their type of construction, in the field of ventilation, heat flow and spread of pollutants.

The analysis of enthalpy control strategies and its application in hot and humid climates

Air enthalpy control strategy, or often known as free cooling, has been very effective in conserving building air-conditioning power consumptions-in moderate climatic areas. However, it stands for a challenge on its application in hot and humid areas, such as in Taiwan, where outdoor air enthalpies are constantly high. Three control schemes, namely, those using temperature control (economizer, or T-control), enthalpy control (H-control), and the Modified temperature control (MTcontrol) were studied in this paper.

Techiniques for simultaneous simulation of buildings and mechanical systems in heat balance based energy analysis programs

The current generation of building simulation software is based upon separate building and mechanical system simulations. While separate simulations are adequate for some buildings, there are many configurations which require a simultaneous simulation to completely model the interactions between the building and mechanical systems. Work is underway to develop a new version of the Building Loads Analysis and System Thermodynamics (BLAST) [1] energy analysis program which will simulate buildings and mechanical systems simultaneously.