A survey of mathematical models of air flow and of ventilation efficiency. Measuring equipment for laboratory experiments is described and the limitations and potential uses of the models are discussed.
Formaldehyde dosimeters have been tested in urea-formaldehyde foam insulated Canadian homes in which formaldehyde levels range from 0.02 to 0.2ppm. Performance of commercial and experimental passive dosimeters was evaluated over 2- to 4- and
Describes laboratory tests to find correct operative conditions for a controlled outside air intake through the air space in the window to provide efficient ventilation without creating draughts.
Characteristics of the air velocity were measured at 500 points in the occupied zone of 20 typically ventilated spaces. A relationship between the mean velocity and the standard deviation was found at four heights above the floor. The turbulence intensity varied from 10 to 70% at ankle level (0.1 m) and from 20 to 55% at head level. This is similar to the experimental conditions under which the draught chart by Fanger and Christensen was established.
A booklet for consumers explaining the effects of house-tightening measures on pollutant levels. It also provides a guide to detecting and controlling pollutants commonly found in homes.
Reviews the scientific literature on indoor air pollution. Low-pollution design and construction techniques employed in the Sunnyhill Low-Pollution Research Centre are outlined in detail and suggestions are made on their applicability to new and existing housing in Canada. The study recommends a four-fold approach to the indoor air pollution problem by government and the building industry: A) short-circuit major potential hazards, B) deal with low-pollution housing needs, C) spread and apply present knowledge, and D)foster more research and discussions on regulation.
A single family residence in St. Paul, Minnesota, constructed in 1957, was retrofitted in 1983. This resulted in approximately 50% reduction in annual heating consumption compared to the average consumption over the previous three years. However, the occupants complained of poor air quality. Measurements indicated that total particulates, CO, CO2, relative humidity, and temperature were at levels of some concern; NO2, radon and formaldehyde concentrations were not significant.
Discusses guidelines produced for the Nordic Ventilation Group. Explains how the designer can select an effective ventilation system on the basis of information on ventilation rates and ventilation efficiency.
Covers maximum permissable levels of various substances, including tobacco smoke, asbestos and benzole, found indoors. The reduction of formaldehyde levels is given special attention.