The multiple spaces equation of ASHRAE Standard 62-1989 makes it possible to bring in a smaller fraction of outdoor air than that dictated by the critical space. This paper develops an analytical proof that increasing the primary airflow rate to t e critical space reduces the outdoor airflow rate required to meet ventilation requirements. For systems employing fan-powered boxes, where more than one box is critical, a systematic procedure for incrementally increasing the primary air is currently required.
This paper traces the evolution of the concept for the Memorial Tunnel Fire Ventilation Test Program conducted in West Virginia during the period 1989-1995. It clearly identifies the objectives set forth for the program by the technical evaluation committee (TEC) representing ASHRAE Technical Committee 5.9
The Central Artery/Tunnel (CA/I) project, currently under way in Boston, Massachusetts, is the largest interstate highway program in the United States. Estimated at $8 billion, the project will generate more than 50 lane-km of new vehicular tunnels and will accommodate more than 300,000 vehicles per day in design year 2010. A direct result of the planning and design efforts on the CA/I is the Memorial Tunnel Fire Ventilation Test Program, recently completed in a full-size facility in West Virginia.
In order to design an environment-conscious house, it is desirable for summer indoor environment, to re-examine thermal conditions warmer than thermal comfort. The role of air movement is important, as it reduces the magnitude of discomfort. This paper discusses the comfort produced by air movement considering two main sensations; coolness and strength of movement, based on results obtained by a series of experiments carried out with five male and five female subjects.
Hokkaido is distinguished from the other island of Japan by having colder winters and cooler summers. The average monthly minimum is about -10 °C and summer daily average maximum around 25°C, so that efficient space heating becomes the dominant aspect But on hot days the temperature may reach 35°C, though for short period of time. There are few houses constructed to prevent overheating ID summer. I have designed and built a house for my family ID Sapporo which has cavity walls of concrete blocks insulated with urethane 100mm thick and deeply recessed, but operable widows.
A purpose of this research work is to study the environmental control in large indoor stadiums which utilize the natural ventilation. In these problems, effects by the airflow in and around the stadium should be analyzed. In this research work, a numerical analysis technique which enables simultaneous simulation of indoor airflow and the airflow around buildings was developed adopting composite grid coordinate calculation technique. In this paper, an outline of this technique is described.
This study was conducted to determine how sash movements affect the performance of fume hoods. The performance of two fume hoods was studied as the sashes were moved from closed to open position at speeds of 2 ft/s, 1.5 ft/s, and 1 ft/s. The tests were conducted with fume hoods operated at both constant volume and variable air volume. The tests indicate that sash movements can disturb airflow patterns at the face of the hood and potentially affect the performance of the hood. The effect of the sash movement varied with hood type and speed of sash movement.
Applicability of CFD simulation to designing passive architectures was investigated using a passive solar room with a Trombe wall system inside it. In the investigation non-steady numerical simulation was performed to predict thermal environment in the test room. Two weather models assuming a typical fine winter day were compared, one was the model based upon the data in Osaka and the other was that in Sapporo. The test room has glazing in the south side wall and in the north side one. Each glazing was covered with an insulating door during night.