On the cooling potential of earth to air heat exchangers.

The present paper deals with the cooling potential of earth to air heat exchangers. The cooling system consists of an underground pipe laid horizontally where ambient or indoor air is propelled through and cooled by the bulk temperature of the natural ground. The dynamic thermal performance of the system during the summer period and its operational limits have been calculated using an accurate transient numerical model. Multiyear soil and ambient air climatic measurements have been used as inputs to the model.

Design criteria for air filtration in general industrial ventilation.

There has been lack of fact-based knowledge for design and operation of supply-air filters for general industrial ventilation. A multi-company project within the Industrial Ventilation (INVENT) technology programme was started in 1994 to tackle this problem area which is assumed to be the most problematic one, according to the feedback from end-users in several industries, who also made the initiative to this project.

Investigation of the impact of natural ventilation through windows on the thermal comfort.

When talking about air-conditioning systems in buildings people argue with high energy consumption of those systems. They do not take into account that it is not possible in many climates to realise several indoor thermal conditions by merely opening windows.Within the framework of the research project SANIREV, sponsored by BMBF and ROM, the Hermann-Rietschel-lnstitute make tests about the use of window ventilation. For different roomloads and out-door-conditions the room conditions are determined. Now we got the first results.

The efficiency of night ventilation techniques for thermostatically controlled buildings.

A new, integrated method to calculate the energy contribution of night ventilation techniques to the cooling load of a building is presented in this paper. The method is based on the principle of "Balance Point Temperature" and permits the calculation of the energy required to cool a building to acceptable comfort conditions when night ventilation techniques are used. It also permits the calculation of the energy contribution of night ventilated buildings compared to conventional air conditioned buildings.

Indirect evaporative cooling of low energy building.

With the growth of living standards, there is an increasing demand for the cooling of living space. Rational energy use demands the use of alternative ways of cooling because the energy consumption of compressor cooling is high. In this article a new cheap and efficient paperboard compact heat exchanger and indirect evaporative cooling are presented.

Tools for evaluating domestic ventilation systems (IEA Annex 27).

This paper is describing the preliminary results of the Annex 27 work aiming at developing simplified tools for evaluating domestic ventilation systems. In this paper is given the tool to evaluate a system's ability to deal with different indoor air quality (IAQ) matters. In the work is used sophisticated simulation programs studying pollutant concentration either for each person or in an individual room. The evaluation is to be applied on houses that mainly are heated. This means that the tools are restricted to the heating season.

A methodology for the practical assessment of natural ventilation designs in industrial buildings with reference to the indoor thermal comfort.

The design of natural ventilation devices in industrial buildings is complicated by the nonlinear interaction between the air flow rate and the indoor air temperature. Designs are therefore usually based on relatively simple calculations of the areas of ventilation openings to provide a specified flow rate at a given indoor/outdoor air temperature difference. However, the practical performance testing required for acceptance of the ventilator design still remains a difficult and dubious task.

Pages