HVAC ductwork: constant-injection tracer-gas assessment of airtightness.

Constant injection of tracer gas was used to determine the airtightness of a straight length of300 X 300 mm square duct in a laboratory setting. Holes are performed in the ductwork which is connected to a fan with variable speed control to simulate leakages. The holes can be sealed with rubber bungs to simulate an airtight ductwork. 'Stationary' and 'mobile' methods have been developed. The stationary method is suitable for conditions where the locations of the leaks in the ductwork is known.

Efficient plans run into reality.

                   

Turbulent particle loss augmentation in a ventilation duct.

Particle loss augmentation in turbulent flow was studied experimentally. Experiments were performed in a I SO mm square ventilation duct. Small tracer particles of size ranging from 0.7-7.l μ.m were used to study deposition enhancement with streamwise-periodic disturbances mounted on one of the principal walls, under turbulent flow. A new and highly sensitive analytical technique was adopted to determine the spatial mass flux along the ribbed duct. On some surfaces, particle deposition enhancement as much as seven times higher than on .smooth surfaces was observed.

Ventilation systems for buildings in urban areas.

The properties of particulate filters and gas adsorption filters have been studied to determine the opportunities available for effectively cleaning the outdoor air supplied to buildings located in urban environments. Class F85 fine filters were studied to determine their collecting efficiency for both atmospheric dust and particulate P AH. Activated carbon adsorption filters were tested to establish their collecting efficiency for toluene, m-xylene and benzene in the concentration range of 1-10 ppm. Long-term tests were also run on a carbon filter in a building in central Stockholm.

Indoor air pollution exposures of low-income inner-city residents.

This report is based on a pilot project for a large epidemiologic study of inner-city asthma, in which exposures to air pollutants will be related to both incidence and prevalance of asthma. Nitrogen dioxide concenmuions were measured in three rooms as well as outdoors in 44 inner-city apartments with gas cooking stoves. Fifty-two separate month-long series of 48-h time-integrated NO, sample. (Palmes tubes) were gathered from fall 1982 to spring 1984. The 48-h average N02 concentrations taken within homes frequently exceeded the U.S.

Deflection of wall-jets in ventilated enclosures described by pressure distribution.

The pressure field in fluid systems reflects the flow configuration. Measurements of the pressure along the perimeter of a slot ventilated room have been conducted for different room sizes. The momentum of the jet at the end of the room is decreased with increasing room length. The impingement region (region where the influence of the opposing wall is present) starts, independent of room size, when the distance from the supply device is about 70% of the room length. Corner flows could not be predicted by CFD using the linear eddy viscosity or standard stress models. However.