Wind pressure and thermal forces are driving forces for pressure difference on the building envelope. In European and German standards infiltration is calculated using wind speed, temperature difference and wind pressure coefficients result-ing from upstream and downstream flow on the building envelope. This long term measurements shall present measured pressure differences on the building envelope in comparison to those calculations.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:40
In high density occupation rooms, it is necessary to control indoor air quality (IAQ) combined with other comfort parameters. An adequate IAQ in classrooms enhances children learning and academic results are improved.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:37
Renewable energy sources for heating and cooling buildings usually have temperatures close to room temperature and therefore a limited convertibility potential, i.e. they are of low value. To exploit low-valued energy sources Low Temperature Heating and High Temperature Cooling (LTH-HTC) systems must be developed.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:35
Displacement ventilation (DV) is an alternative to conventional mixing ventilation in various types of rooms. DV is superior to mixing ventilation when it comes to removing contaminants and surplus heat in a room if designed and applied correctly. In the design process of a space with DV it is necessary to have design methods and simulation tools that can predict the vertical contaminant stratification that arise.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:32
In 2008 the State of California adopted new building codes that required the use of mechanical ventilation systems in homes that meet the requirements of ASHRAE Standard 62.2. The standard requires both a dwelling unit mechanical ventilation system and exhaust fans in kitchens and bathrooms. A field study was undertaken to evaluate the IAQ and ventilation performance of homes built to these requirements. For ventilation system performance, the airflows of all mechanical ventilation systems were measured and their use was monitored for a one-week period.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:30
A key aspect of achieving acceptable indoor air quality is source control. Cooking has been recognized as a significant source of pollutants for health impacts (e.g., PM2.5 and NO2) as well as moisture and odour. A common method of controlling this pollutant source is by using a range (or cooker) hood that vents to outside. However, field and laboratory experiments have shown highly variable performance for these devices. We use the capture efficiency metric (the fraction of the pollutants that are exhausted to outside at steady state) to characterize the range hood performance.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:15
Last years, interest in airtightness increases among all construction fields and airtightness becomes a major issue in the reduction of energy consumption in buildings. Nevertheless, there is a lack of understanding of air displacements through weak spots in buildings (airpaths). Firstly we develop first the concept of Potential Improvement Graph (PIG chart). These graphs represent the “improvement curves” of a given airpath (airflow indicator against airpath parameter). As an airpath can have multiple significant parameters, PIG charts can be n-dimension graphs.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:13
Nowadays, due to the higher energy performance of dwellings, ventilation plays an increasing role in maintaining a good indoor comfort. Therefore new ventilation strategies in combination with demand controlled ventilation are needed to accomplish high energy-efficient ventilation (limiting ventilation losses and auxiliary energy consumption) while providing good indoor air quality, thermal and acoustic comfort.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:11
Night ventilation is used extensively as a low energy strategy to cool buildings in climates where night temperatures are suitable. It can be used for spaces utilising natural or mechanical ventilation systems as well as active refrigerant cooling. Most published work focuses on domestic and relatively simple in operation commercial buildings such as offices. This paper presents a study of the cooling benefits of night ventilation for frozen food supermarkets with high cooling demand.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:09
A “heat recovery hybrid ventilation system” is the combination of passive stack ventilation and mechanical push-pull ventilation. Two heat storage boxes are connected to the natural EA stack and the underfloor natural OA duct. The alternation is done periodically in a way of that the outdoor air is drawn through one of 2 boxes contains earth tiles and the indoor air is exhausted through the other box.