Accuracy requirements and limitations for low velocity measurements.

Recommendations for the characteristics of anemometers that will ensure accurate velocity measurements are specified in the present standards. Recent research shows, however, that the requirements in the standards are based on incorrect assumptions and are insufficient to perform draught discomfort assessment that meets the accuracy requirements for human comfort specified in the indoor climate standards.

Average versus simultaneous climatic data for estimates of natural ventilation cooling potential.

Airflow through houses from onshore coastal breezes in warm humid tropical climates is the principal passive means of achieving indoor thermal comfort when air temperatures exceed 30°C and relative humidity exceeds 60%. Estimates of indoor natural ventilation cooling potential have been based on indoor wind speed coefficients determined from boundary layer wind tunnel tests combined with wind frequency, air temperature and relative humidity data.

Investigation of the emission and immission behaviour of livestock buildings by means of wind tunnel modelling.

The keeping of animals in livestock buildings requires the ventilation of these buildings. Good climate conditions for the animals have to be guaranteed as well as little emissions and immissions from the livestock buildings. An important role for both of these opposite requirements plays the airstream inside and outside of the building. For this reason wind tunnel modelling and digital imaging by using a laser light sheet is applied beside other methods at the Institute of Agricultural Engineering Bornim.

The application of CFD to large scale industrial premises.

This paper introduces a research programme investigating the application of CFD to large scale industrial premises. A number of modelling issues and two case studies are discussed. The research programme will lead to an increased degree of confidence of CFD simulation results in complicated environments.

Transition from bi-directional to unidirectional flow in a doorway.

The air flow in a doorway is governed by density difference caused by temperature difference and pressure difference caused by mechanical ventilation. Tests have been carried out in a unique indoor test house where the room to room to temperature difference could be controlled very accurately with a new control system. In addition to these tests some tests were carried out in a scale model with water as the operating fluid. Two main criteria of unidirectional flow in a doorway have been explored:

CFD simulation of air velocity distribution in occupied livestock buildings.

In modem livestock buildings the design of the ventilation systems is important in order to obtain good air distribution. The use of Computational Fluid Dynamics for predicting the air flow and air quality makes it possible to include the effect of room geometry, equipment and occupants in the design of ventilation systems. However, it is not appropriate to include the detailed geometry of a large group of lying or standing animals affecting the air flow in the building. It is necessary to have relatively simple models of the animals, which are easier to implement in the computer models.

Pages