Numerical prediction of mixed turbulent airflow within a cavity using various turbulence models.

The overall objective of the present work is to evaluate the performance of three turbulence models, with a view to predicting characteristics of airflow within an anisothermic cavity. The standard K-c. model, the Renormalisation Group model (RNG) and the Reynolds stress model (RSM) are used in conjunction with the Fluent code. The accuracy and the relative performance of the three models are evaluated by comparing their numerical results with experimentally obtained data. This comparison is made for the constant flow rate of a twodimensional turbulent mixed convective airflow.

Greenhouse natural ventilation by buoyancy forces.

Convective transfers mainly determine the energy and mass balances which regulate the micro-climate inside a greenhouse. Air flow and temperature patterns induced by natural ventilation through greenhouse roof openings are only considered here. Flow visualizations were performed on a half scale test cell simulating the absorption of solar radiation at the floor surface of a single-span greenhouse. Temperature and air flow patterns were observed in a steady regime i) with a single sided roof vent and ii) with two symmetrical one.

A novel concept of facade for daylighting and natural cooling.

The role of metallic surfaces is not only to save energy in winter and in summer by separating the inside and the outside. New and inexpensive ways of collecting solar energy for internal heating, new ways of ventilating, heating and cooling through the fabric elements are described. Two very significant prospects are : radiative cooling by metallic surfaces and enhancement of indirect daylighting by optimised ceilings. The subject of the European CURES program is to promote these new technologies by simulating and testing them.

Wind driven and thermal air flow patterns at courtyards.

Air flow patterns and temperature distribution within courtyard have been studied. Wind and thermally driven flow have been thoroughly analysed as a function of the depth to width ratio (Aspect ratio) as main parameter. CFD results show a quite similar behaviour regarding to velocity profiles for all the cases, though temperature profiles are highly affected by dimensions of the courtyard. The whole study can be extrapolated to urban canyons, where air flow patterns are quite similar as a result of having the same geometry.

An experimental study on the ventilation control related to the envelope of a new airport terminal.

Over the last decades, a great importance has been given to thermal insulation, in technological designing of building envelope. Lately, a basic requirement of indoor air quality, strictly related to ventilation control strategies, has been highlighted. Then, it is necessary to evaluate correctly, during the design phase, the air permeability of enclosures through validated methods, to assess new technologies through laboratory tests on prototypes and finally to verify real performances through on-site testings.

Road traffic pollution and its effect on the internal environment of buildings.

Indoor and outdoor concentrations of various pollutants were measured in a naturally ventilated building in the West End of Edinburgh during and after the period of the Commonwealth Heads of Government Meeting (CHOGM) to assess the effect upon indoor pollution levels of the closure of some streets in the city. The relationships between indoor and outdoor air qualities in respect of traffic-generated pollutants were studied and the building's relative attenuation of external pollution levels investigated.

Relative importance of temperature, draft, noise and window area in offices.

Achieving optimized partial improvements of the indoor climate may often be better than to know all optimal levels. The purpose of this study was to investigate the relative importance of temperature, noise, draft and window area. 30 heat-acclimatized subjects participated in 10 exposures in single person climate chambers. Each exposure lasted three hours. During an exposure, the subject was free to optimize the operative temperature at a link to either draft, noise or window area. For each pair of parameters, three linear links were tested.

Measurement of air flow rates and ventilation efficiency in air handling units.

The use of tracer gas is of great help in measuring airflow rates and detecting shortcuts in air handling units, and is essential for ventilation efficiency measurement. However, the planning of experiments, that is choosing tracer gas injection locations and air sampling locations, is not straightforward. Moreover, the mathematics used for interpretation are quite complex, and require elaborate calculations. Therefore, a measurement protocol and the corresponding interpretation algorithms are being developed and implemented in a user-friendly computer program.

Overview and synthesis of the monitoring activities carried out in the framework of the NatVent EC Joule Project.

Since the beginning of this decade, natural ventilation in office buildings is receiving specific interest. There are two sorts of application. Natural ventilation can be a strategy for indoor air quality control. Besides it can be used as night ventilation during warm or hot periods. In this case the objective is to cool down the thermal mass and improve the thermal summer comfort. The EC JOULE NatVent project wanted to identify the barriers to the application of natural ventilation in office-type buildings in moderate and cold climates and to provide solutions.

Building acoustics and sick building syndrome.

The acoustic environment was examined in an office building with a high prevalence of symptoms typical of the sick building syndrome (SBS). Levels of ventilation noise exceeded 70 dB in many rooms. The peak was often found in the region below 20 Hz, which is the infrasound region and generally regarded as inaudible at these levels. Symptoms attributed to exposure to low frequencies include nausea, headache, choking, coughing, visual blurring and fatigue, which appear to overlap with some of the symptoms of SBS.