Wind protection by model fences in a simulated atmospheric boundary layer

Reports wind tunnel tests of wind velocity, RMS velocity fluctuations and energy spectra for the streamwise velocity component in the lee of model fences of permeability 0% 20%, 34% and 50%. Compares results with existing field and wind-tunnel data. Turbulence measurements define the leeward flow regions which are dominated respectively by the bleed flow and by thedisplacement flow. Gives separate empirical relationships between mean velocity and turbulence intensity for these two regions.

Source and importance of air pollution in the interior of buildings. Source et importance de la pollution de l'air a l'interieur des batiments.

Describes a sampling programme which measured simultaneously the indoor and outdoor concentrations of pollutants at three sites in Zurich during summer and winter. Gives brief summary of results showing concentrations of CO, NO, NO2 and HCHO and discusses sources of the different pollutants.

Practical methods of reducing airborne contaminants in interior spaces.

Air contaminants include all gases, vapours, liquid droplets and solids, including microogranisms of small size that can be dispersed in air and that are unwanted. Contaminants can be removed by dilution of the air, by deposition of particles on surfaces or by reaction with other materials in air or in space (such as furnishings).< This article discusses in general terms the reduction of contaminants and gives equations of concentrations of contaminants after time t. Discusses types of filters and their effectiveness.

1 Infrasonic impedance measurement of buildings for air leakage determination.

Reports preliminary research directed towards developing a new method for measuring the air leakage property of an enclosure. The low-frequency acoustic impedance of the enclosure is measured by an infrasonic method. Describes and analyses a diaphram-type motor-driven source and a pressure sensor with electronic filters used to measure infrasonic impedance.< Reports tests run in enclosures of different volumes and degrees of leakiness.

Infrasonic measurement of building air leakage-a progress report.

Describes infrasonic method of measuring the air leakage of a house or apartment. Describes apparatus, consisting of a motor driven source of known output a sensitive pressure pickup and anelectronic signal processor. A low frequency (about one cycle per second) alternating air flow of known magnitude is applied to the interior of the building, and the alternating component of inside pressure that results is measured. The pressure response is a function of the type and size of leakage paths. Describes measurements made on three interior rooms and gives sample results.

A comparison of wind-tunnel and full-scale wind pressure measurements on low-rise structures

Reports comparisons between wind pressures measured on two low-rise experimental buildings and pressures measured on wind-tunnel models of those buildings. For the experimental building at Aylesbury, comparisons are made between thefull-scale pressures obtained by the Building Research Establishment and those of model tests at 1: 500 scale carried out by the University of Western Ontario, Canada and at 1 :50 scale by Virginia Polytechnic Institute and State University (V.P.l.S.U.). The second experimental building, constructed by V.P.l.S. U.

Wind shelters.

Reports study of the aerodynamics of wind breaks in a boundary layer wind tunnel. Describes flow patterns and shelter effects in the lee of different fences and discusses efficiency of shelters in relation to pedestrian comfort. Gives results downstream in horizontal planes by nets of isocurves showing mean speed and turbulence. Discusses the influence of permeability, shape, size and wake ventilation and suggests new designs: for example two wind breaks in series.

Wind pressure coefficients on exterior wall elements of tall building.

Reports measurements of wind pressure distributions on a model of tall building made in a turbulent wind tunnel with a velocity gradient. The wind pressure distributions in a constant uniform velocity field were also measured and the differences in thepatterns of pressure distributions due to the effects of velocity gradient were observed at lower part of the model.< Also describes measurement of natural wind pressures and glass strains on a 36 storey office building. Finds inter alia considerably large pressure fluctuations of short gusts although average pressures are small.

How to build a superinsulated house.- Cold weather edition.

Gives instructions for constructing a super-insulated house. Describes installing insulation, vapour barriers, shutters and an air-to-air heat exchangers. Outlines ways in which heat islost from a house and the problems of conventional structures.

Well insulated airtight buildings, energy consumption, indoor climate, ventilation and air infiltration.

Reports study of indoor climate-primarily air quality-and energy consumption in a number of detached houses in a group housing area. All the houses were pressure-tested over three years; 1977-1980 and a relatively larger increase in air leakage was measured after the houses had been occupied for approximately one year. Suggests this is due to the drying out of timber, producing cracks. Two types of houses, a and b were investigated when studying indoor climate. both were mechanically ventilated.