The project described in this paper has performed simulations using a multi-zone air flow model (4(COMIS)) of three different passive stack ventilation systems. The objective of the simulation calculations was to evaluate system performances and to make suggestions for possible improvements of the systems.
Ventilation by displacement is a type of ventilation where the air flow is thermally driven. By this arrangement one obtains two zones in the room - a lower zone with supply air conditions and an upper recirculation zone with extract air conditions. Cold climate causes downdraught from windows and external walls and results in a mixing of air from the upper into the lower zone. To avoid this problem during cold climate a new principle for ventilation by displacement is tested. Excess heat from the upper zone of the room is used for heating cold surfaces.
Since 1985 more than 170 very low energy houses, all of the same type and structure, were built in the Flemish Region, Belgium. Because conduction losses are very low, mean Urn-value 0.30-0.35 W/(m².K), ventilation losses become very important, up to 45% of the heat losses if no heat recovery is utilised. Three of the houses were monitored in detail for energy consumption, energy and ventilation efficiency. All houses are equipped with the same ventilation system: balanced mechanical ventilation with heat recovery.
Electric utilities in the Pacific Northwest have spent over $100 million to support energy efficiency improvements in the HUD-code manufactured housing industry in the Pacific Northwest over the past several years. Over 65,000 manufactured housing units have been built since 1991 that exceed the new HUD standards for both thermal performance and mechanical ventilation that became effective in October, 1994. All of these units included mechanical ventilation systems that were designed to meet or exceed the requirements of ASHRAE Standard 62-1989.
This paper reports on work carried out at BRE to address the need for guidance on designing for natural ventilation via single-sided and cross-ventilation in office spaces and the limits of application in terms of plan depth. Present guidance suggests that natural ventilation will be adequate up to 6 m from the ventilating facade. This leads to the conventional design of offices up to 6 m deep on either side of a central corridor, giving as a rule of thumb a width of 15 m for a building with natural cross-ventilation.
This paper describes an experimental investigation into the operation of a modified Trombe wall. The construction has been altered to include a layer of insulation material; two alternative positions for this insulation layer have been considered and tested. Air flow from the top of the Trombe wall has also been enhanced by the inclusion of a low power axial flow fan which was controlled to function dependent on measured temperature in the wall cavity.
This paper describes the ventilation analysis undertaken during the design of a new music centre for which it was desired to avoid the use of air conditioning and conventional ducted mechanical ventilation. The main objective was to predict the thermal comfort of occupants in the centre's main auditorium during summertime performances. The analysis was done using computational fluid dynamics (CFD) and a dynamic thermal model.
The work described in this paper is aimed at predicting the local values of the ventilation eflectiveness parameters of large industrial buildings by a technique which involves the use of computational fluid dynamics and multizonal modelling. A modelling technique is described and applied to a typical modern industrial building equipped with both, mixing and displacement ventilation systems. The results of modelling each of the above systems are presented and discussed.
Natural ventilation is being applied to an increasing number of new buildings to minimise reliance on mechanical ventilation and so reduce emission of greenhouse gases. However, passive stack ventilation (PSV) systems are currently designed without incorporating heat recovery leading to significant wastage of energy. Heat recovery systems have not been used in naturally-ventilated buildings because the pressure loss caused by a conventional heat exchanger is large compared to the stack pressure and could cause the ventilation system to fail.
A study of the reliability of systems by considering the ability of different systems to maintain a required air flow rate over time is included in a subtask of IEA Annex 27 "Evaluation and Demonstration of Domestic Ventilation Systems". Measurements and calculations were performed to determine the variation in ventilation rates due to variation in climate and variation in performance of the ventilation system. Dwellings with passive stack, mechanical exhaust and mechanical exhaust-supply ventilation, representative of the Swedish housing stock, were studied.